RECOMMENDATION & SAFETY REQUIREMENTS 

  Other documents, which may be appropriate for your applications, are available on request. 

CODE 

IDENTITY 

DESCRIPTION 

X10255

 

SRA

 

Safety requirements: Addressing the Low Voltage Directive (LVD) including, 

Thermal data/cooling, Live parts warning Earth requirements and Fusing 
recommendations.

 

P01.1

 

COS

 

UAL Conditions of sale.

 

NOTE: 

It is recommended that installation and maintenance of this equipment should be carried out by suitably 

qualified personnel, with reference to the current edition of the I.E.E. Wiring Regulations BS7671.  The 

regulations contain important requirements regarding the safety of electrical equipment.   

 

 

   

 

 

Not for general waste  

 

 

ADDITIONAL INFORMATION 

When using a remote switch it is important that an additional cable gland (not supplied) is used to 
ensure the IP rating is maintained. 

The rear of the enclosure contains the PCB; this will need to be removed before attempting to fit the 
additional cable gland.   Remove the four fixing screws and remove the PCB.   The ‘knock-out’ can then 
be removed and the additional gland fitted as shown above.  This should be done very carefully - 
ensure the gland is tightened up using a spanner.   Refit the PCB and secure with the screws.  

Remove the link that is fitted into the INPUT/COM terminals and wire in the switch wires.   

Once the additional gland has been fitted the units should be mounted as shown above. 

This is the only time the unit should be mounted in this way.  If the additional switch is not being used 
then the unit must be fitted with the gland facing down.   Once the unit is wired, the lid should be refitted 
as shown.   

CE MARKING 

This product family carries a “CE” marking.  For more information see RECOMMENDATIONS section 
and contact our sales desk.  A Declaration of Conformity is available on request. 

Содержание INFRESCO-S-4kW

Страница 1: ... Issue 2 User Manual Date 12 06 18 Page 1 of 6 KEY FEATURES Extends lamp Life Ideal for controlling up to 2 x 2kW lamps Soft start zero voltage switch off Low cost Easy to install Power ON Blue Heater ON Red LED indication ...

Страница 2: ...d to access the mounting holes To ease installation a mounting template is provided on the next page to locate the 4 mounting hole centres IMPORTANT The unit must be positioned with the cable glands facing down Wiring Warning Ensure all earth wires are connected to maintain earth continuity to the lamp fittings Isolate the mains supply before wiring this unit The unit is fitted with two cable glan...

Страница 3: ...unting Template Use this template to locate the 4 mounting hole centres prior to drilling IMPORTANT The drilling of any additional holes will immediately void the warranty of this unit The unit must be positioned with the cable glands facing down ...

Страница 4: ...Page 4 of 6 WIRING DIAGRAM Link Must be fitted to Enable Unit ...

Страница 5: ... used to ensure the IP rating is maintained The rear of the enclosure contains the PCB this will need to be removed before attempting to fit the additional cable gland Remove the four fixing screws and remove the PCB The knock out can then be removed and the additional gland fitted as shown above This should be done very carefully ensure the gland is tightened up using a spanner Refit the PCB and ...

Страница 6: ... 4 H Q T e l 4 4 0 1 7 0 4 5 1 6 5 0 0 F a x 4 4 0 1 7 0 4 5 1 6 5 0 1 e m a i l s a l e s u n i t e d a u t o m a t i o n c o m W e b w w w u n i t e d a u t o m a t i o n c o m PRODUCT APPLICATIONS Garden Lighting Patio Areas Smoking shelters Restaurants Warehouses Workshops Livery stable ...

Отзывы: