![Uniteck UNIPOWER 150.12Q Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/uniteck/unipower-150-12q/unipower-150-12q_user-manual_4497921038.webp)
38/68
WWW
.
UNITECK
.
FR
EN
TROUBLESHOOTING
UNIPOWER 2000.12Q and 2000.24Q
Troubleshooting
Causes
Remedies
Unipower does not deliver
current anymore
+
Sound alarm on the inverter
+
The remote display indicates
"Err Low"
Discharged battery
Recharge your battery or replace it,
if it is defective.
24V>230V inverter :
battery not suitable (12V
instead of 24V)
Replace your 12V battery by a 24V
battery.
Battery/inverter connection is
defective
Check your connections (cables,
terminals, tightening...)
Unipower does not deliver
current anymore
+
Sound alarm on the inverter
+
The remote display indicates
"Err high"
Battery overvoltage
Check that the battery voltage is
compatible with the inverter.
Replace the battery if it is defective.
Unipower does not deliver
current anymore
+
Sound alarm on the inverter
+
The remote display indicates
"Over Load"
Overconsumption
Recharge your battery.
Unipower will restart when the
battery voltage will be acceptable.
Replace the battery if necessary.
Unipower does not deliver
current anymore
+
Sound alarm on the inverter
+
The remote display indicates
"Over Temp"
Thermal protection : the
inner temperature of the
inverter is above 45°C
Stop the consumer. Let the inverter
cool down and improve the
ventilation.