COMPLIANCE STATEMENT 

 

 

The UNITECK testifies that UNISPLIT 160.12 described in this manual is manufactured according to the 

requirements of the following European directive: 
 
- Low Voltage Directive: 2004/108/CE from 15/12/2004 

It complies to the harmonised standards: 
- EN 61000-6-3: 2007 EMC Emission 
- EN 61000-6-1: 2007 EMC Immunity 
- 95/54/EC: 1995 
- ISO 8092: 2005 

 

 

CE date of tagging: January 2015. 

 

01/01/2015 

Yoann Fourmond

 

Société Uniteck 
1 Avenue de Rome  

General Director 

Zae Via Europa 

  

Immeuble le Cassis 
34350 Vendres 
France 
Mail : [email protected] 
Fax 

: + 33 (0) 4 88 04 72 20 

 

 

 

 

WARRANTY 

 

 

Warranty covers any defect, manufacturing defects  for 1 year from the date of its purchase (parts and 

labour). 

 

Warranty does not cover: 

- normal wear of parts (Ex.: cables, etc.).  
- panel-module/battery voltage errors, incidents due to inappropriate use, fall, disassembly or any damages due 

to transport.  

 
In case of failure, return the product to your distributor by attaching: 

the dated proof of purchase (receipt, bill…)

 

- explanatory note of the failure 

 

Caution: Our after-sales service does not accept carriage forward/ collected returns. 

 

After the warranty, our after-sales service ensures repairs after acceptance of a quotation. 
After-sales service contact : 
Uniteck- 1 Avenue de Rome 
Zae Via Europa - bâtiment Cassis 
34350 Vendres -France 
E-mail : 

[email protected]

 

Fax : +33 (0)4 88 04 72 20 

Содержание 210035014

Страница 1: ...26 07 2021 www uniteck fr CO00109 Coupleur separateur Isolator Combiner Acoplador separador ES EN FR UNISPLIT 160 12...

Страница 2: ...midit de la poussi re et de la condensation Suivre les instructions de s curit du fabricant de la batterie En cas de doute consulter votre revendeur ou installateur Les batteries sont susceptibles de...

Страница 3: ...on vite que la batterie 2 auxiliaire ne soit connect e au moment du d marrage 4 La deuxi me batterie est coupl e et donc en charge 5 UNISPLIT s pare les 2 batteries soit en charge lorsque la tension d...

Страница 4: ...asse a Pour un usage avec alternateur connectez la borne 86 de l UNISPLIT sur le apr s contact NB le apr s contact peut tre connect dans le boitier de fusibles au branchement de l allume cigare notamm...

Страница 5: ...seill e L1 L2 L3 L4 1 m tre 2 m tres 3 m tres 4 m tres 5 m tres 6 m tres Section 6 mm 10 mm 16 mm 25 mm 35 mm 50 mm 2 Raccordement site isol avec chargeur de batterie Section c ble conseill e L1 L2 L3...

Страница 6: ...onnement 9 15V DC Consommation relais ouvert ferm 10 mA 600 mA Tension de d connexion 12 8V Tension de reconnexion 13 4V D lai de connexion 10 sec 5 Courant nominal 160A Courant cr te 500A pendant 1 S...

Страница 7: ...10 secondes apr s seuil de connexion Attendre ce d lai Pas de charge Contr lez l tat de votre alternateur ou de votre chargeur Mauvaise connexion V rifiez vos connexions de c bles c bles de puissance...

Страница 8: ...r Fax 33 0 4 88 04 72 20 GARANTIE La garantie couvre tout d faut ou vice de fabrication pendant 2 ans compter de la date d achat pi ces et main d uvre La garantie ne couvre pas l usure normale des pi...

Страница 9: ...apted for this purpose For optimum operation it is advised to use batteries of similar capacities 20 WARNINGS UNISPLIT is designed to be used exclusively with 12V lead acid gel electrolyte Gel sealed...

Страница 10: ...of battery 1 or 2 or ground a For a use with alternator connect terminal 86 of UNISPLIT On the after contact of the starter after contact examples electric cigarette lighter b For a use with charger c...

Страница 11: ...section L1 L2 L3 L4 1 meters 2 meters 3 meters 4 meters 5 meters 6 meters Section 6 mm 10 mm 16 mm 25 mm 35 mm 50 mm 2 Isolated site connection with battery charger Recommended cable section L1 L2 L3...

Страница 12: ...9 15V DC Relay self consumption open closed 10 mA 600 mA Disconnection voltage 12 8V Reconnection voltage 13 4V Connection timeout 10 sec 5 Nominal current 160A Peak Current 500A for 1 sec at 23 C Op...

Страница 13: ...04 72 20 WARRANTY Warranty covers any defect manufacturing defects for 1 year from the date of its purchase parts and labour Warranty does not cover normal wear of parts Ex cables etc panel module ba...

Страница 14: ...iento ptimo est aconsejado usar bater as de capacidades similares 20 ADVERTENCIAS UNISPLIT est concebido para estar utilizado s lo con bater as de plomo a electr lito l quido GEL sellado de tipo AGM E...

Страница 15: ...tiva del sistema borna de la bater a 1 o 2 o masa a Para un uso con un alternador conecte la borna 86 del UNISPLIT con el despu s contacto del arranque Ejemplos de despu s contacto del arranque encend...

Страница 16: ...sejada L1 L2 L3 L4 1 metro 2 metros 3 metros 4 metros 5 metros 6 metros Secci n 6 mm 10 mm 16 mm 25 mm 35 mm 50 mm 2 Cableado Sitio aislado con cargador de bater a Secci n cable aconsejada L1 L2 L3 L4...

Страница 17: ...o 9 15V DC Consumo relevo abierto cerrado 10 mA 600 mA Tensi n de desconexi n 12 8V Tensi n de re conexi n 13 4V Plazo de conexi n 10 seg 5 Corriente nominal 160A Corriente pico 500A durante 1 seg has...

Страница 18: ...ant a cubre todo defecto o todo vicio de fabricaci n durante 1 a o desde de la fecha de compra piezas y mano de obra La garant a no cubre el desgaste normal de las piezas ej cables etc las errores de...

Отзывы: