Chapter 1
Getting Started
3
Establishing Terminal-PC Connection
Configure MT180 system settings after connecting power through an external power source. MT180
enables users to link to a host computer via Ethernet or RS485 interfaces for data communication.
MT180 can setup through MTTool or JanitorLite.
Unitech MTTool is a development program designed to help technical engineers customize access con-
trol, attendance control and manage function modules in a specified terminal (i.e. MT180). Connect
MTTool to MT180 through the following:
1.
Connect MT180 and a computer to the network.
2.
MT180’s default IP address is
192.168.2.127
. Set the computer on the same subnet with
MT180.
For example, IP Address
192.168.2.100
; Network Mask
255.255.255.0
.
3.
Make sure the TCP port
10002
is not occupied. If yJanitorLite is installed, stop the Unitech MT
Service in the Control Panel.
4.
Disable any firewalls and execute MTTool.
5.
In MTTool, on the computer screen, under the
SysSet1
tab, select
WinSocket
. In the
IP/Name
field, input MT180’s default IP address
192.168.2.127
and in the
Port
field, input the default
port
10002
.
6.
Click
Connect
. The status bar at the bottom of MTTool displays
Connection succeed
, which
means MTTool has successfully cononected to MT180.
RS485
Port
Ethernet
Port