34
5.2.6 Interleaved 2 of 5
Restore Factory Defaults
Restore the Factory Defaults of Interleaved 2 of 5 (default)
Enable/Disable Interleaved 2 of 5
Enable Interleaved 2 of 5 (default)
Disable Interleaved 2 of 5
Message Length
Message length can be set to the maximum value, minimum value. The data between the maximum and the
minimum is valid.
The maximum value and minimum value can be set using Programming Command. Please check the
programming command guide for the detail.
Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80.
Interleaved 2 of 5 min length command: 020403. The parameter of this command can be set from 2 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum value is 25.
Programming command
Max: 02040425.
Min: 02040310.
Interleaved 2 of 5 Check Digit
Содержание MS846
Страница 1: ...1 MS846 User s Manual Version 1 0 Unitech 2D Image Scanner...
Страница 12: ...12 27 Romania 28 Russia 29 Japan...
Страница 18: ...18 3 10 Barcode Scanning Delay No Delay default Delay 500MS Delay 2000ms 3 11 Ship Image Ship Image...
Страница 19: ...19 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB...
Страница 26: ...26 Enable ENA JAN 8 Addenda Separator default Disable ENA JAN 8 Addenda Separator UPC...
Страница 35: ...35 No check Char default Validate and Transmit Validate not Transmit...
Страница 55: ...55 Aztec Append Enable Aztec Append default Disable Aztec Append...
Страница 66: ...66 6 3 Appendix 3 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F...