Page D.5
D.5 Scanner Port:
Enter Group 5
Group Default
0
1
2
3
4
5
6
7
8
9
Terminator:
0
—
Enter
1
—
Return (on digits keypad)
2
—
Field Exit or Right Ctrl 3
—
None
D1
Code ID: 0 – disable
1 – Enable
Note: This setting doesn’t affect EAN128 Code ID.
EAN128 has its own Code ID setting on page D.7.
D2
Define Code ID:
00–Code 39 Full ASCII
01–Code 39 Standard
02–EAN-13
03–UPC-A
04–EAN-8
05–UPC-E
06–Interleaved 2 of 5
07–Codabar
08–Code 128
09–Code 93
10–Standard 2 of 5
11–MSI Code
12– EAN128
13–Code32 (Italian
harmacy)
14–Delta Code
15–Label Code
16–Plessey Code
17– Code 11(Special)
18–China Postal code
(Toshiba Code)
D3
Scan two digits to
choose a code, then
scan a char. From full
ASCII table to define
ID.
Double Verification:
0 – Off
1~7 – On(Verify 1~7 times)
D4
Scanning Mode:
0
–
Trigger Mode
1– Flashing Mode
2 –Multiscan Mode 3–One Press One Scan
4-–Test Mode 5–Old Laser flash Mode
D5
Label Type:
0 – Positive
1 – Positive and Negative
D6
Aim function for long range laser engine
:
0—Disable
1—Enable
D7
Preamble
PP
Postamble
OO
Scan ‘PP\OO’ for Pre\Postamble. Scan characters
from Full ASCII char or Function
Exit