54
3-22 UK/Plessey
Read:
Format
Data digits (variable)
2 check digits (optional)
Check digit verification:
The UK/Plessey has one or two optional check digits. The check digit 1 and
check digit 2 will be calculated as the sum module 10 or 11 of the data digits.
Check digit transmission:
By setting Enable, check digit will be transmitted.
Max./Min. code length:
Refer to Max./Min. code length of “
3-11 Code 39 (Code 32, Trioptic Code 39)
”.
Code ID setting:
Refer to Code ID setting of “
”.
Insertion group selection:
Refer to Insertion group selection of “
”.