background image

035-14446-000 Rev. B  (1002)

Unitary Products Group

3

5.

Install the high altitude conversion labels as described in 
the LABELS sections of this instruction on Page 4.

6.

Refer to the unit installation instructions to complete the 
installation before continuing with these procedures.

TESTS AND ADJUSTMENTS

The following tests must be performed at the time of conver-
sion following completion of the installation.

1.

Connect a manometer to the pressure tap  on both the 
inlet and outlet side of the gas valve. Connect a power 
supply and a gas supply to the unit, if not already con-
nected.

2.

Turn on the gas supply and bleed air from the gas supply 
lines at a point as close to the inlet or the gas valve as is 
practical.

3.

Turn the gas valve control knob to the ON position.

4.

Make sure unit electrical disconnect switch is in the OFF 
position.

5.

Set the room thermostat to call for heat.

Table 3: 

ALTITUDE/NATURAL GAS HEATING VALUE ORIFICE SELECTION

NATURAL GAS

HEATING VALUE

(MANIFOLD 

PRESSURE

3.5" W.C.)

ORIFICE

SHIPPED

WITH UNIT

RECOMMENDED ORIFICE

ALTITUDE (FT. ABOVE SEA LEVEL)

0

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

10,000

1200 BTU/CU Ft.

45

48

49

49

50

50

50

51

51

52

52

43

45

46

47

47

47

48

48

49

49

49

1100 BTU/CU.FT.

45

47

48

48

49

49

49

50

50

51

51

43

44

45

45

45

46

47

47

48

48

49

1000 BTU/CU.FT.

45

45

46

47

47

47

48

48

49

49

50

43

43

44

44

44

45

45

46

47

47

48

900 BTU/CU.FT.

45

44

45

45

45

46

47

47

48

48

49

43

42

42

43

43

43

44

44

45

46

47

800 BTU/CU.FT.

45

43

44

44

44

45

45

46

47

47

48

43

39

40

41

41

42

42

43

43

44

44

Table 4: 

ALTITUDE/PROPANE (LP) GAS HEATING VALUE ORIFICE SELECTION

PROPANE GAS HEATING 

VALUE (MANIFOLD 

PRESSURE 10.0” W.C.)

PROPANE

ORIFICE @

SEA LEVEL

RECOMMENDED ORIFICE

ALTITUDE (FT. ABOVE SEA LEVEL)

0

2,000

3,000

4,000

5,000

6,000

7,000

8,000

9,000

10,000

2516 BTU/CU FT.

54

54

54

55

55

55

55

55

56

56

56

55

55

55

55

55

56

56

56

56

56

57

56

56

56

56

57

57

57

58

59

59

60

Table 5: 

ORIFICE PART NUMBERS

BURNER ORIFICES

Size #

Source 1 Part Number

Blank

029-20423-000

41

029-20423-041

42

029-20423-042

43

029-24243-043

44

029-20423-044

45

029-20423-045

46

029-20423-046

47

029-20423-047

48

029-20423-048

49

029-20423-049

50

029-20423-050

51

029-20423-051

52

029-20423-052

55

029-20423-055

56

029-20423-056

57

029-20423-057

58

029-20423-058

59

029-20423-059

60

029-20423-060

Make sure both gas and power supplies are shut
off before proceeding.

Make sure the space is free of gas before pro-
ceeding.