VX1305 Servers
7017 6300–005
6–9
Configuration Guidelines VX1305
Table 6–7 lists guidelines for configuring VX1305 servers. Figure 6–2 shows the
connection from a VX1305 server to the CIOM card in the CEC module or to the PCI Thru
card in channel racks.
Table 6–7. Configuration Guidelines, VX1305 Servers
Area
Rule/Recommendation
Windows NT Connection
Packages
See Table 6–5 for details
.
Processor Addition
One additional processor may be added to a maximum of two per server
.
See
Table 6–3 for details.
Disk Addition
Additional disk may be added to a maximum of three per server
.
See Table 6–1
for recommendations.
Memory Additions
Three increments of 256 MB can be added to a memory board
.
See Table 6–4.
PCD Generation
Refer to Appendix B of the
A Series and ClearPath HMP NX Systems I/O
Hardware Configuration Guide
(7008 6087)
for information on PCD
generation.
Serial 1
U
U
K
M
LPT
Ser 2
Ser 1
Vid
LAN
0627A
Serial 2
Server A
7019 7488-001
(CSB3-10C)
Remaining Servers
7019 7488-002
(CSB3-15C)
To CS Bus in CEC or PCI
Thru card in channel racks
Figure 6–2. VX1305 Server CS Bus Cable Connection
Содержание NX5820 K
Страница 4: ...Format these characters as white to force printing of blank page...
Страница 8: ...Format these characters as white to force printing of blank page...
Страница 162: ...Configuring Optional and Recommended UPS 6 56 7017 6300 005...
Страница 164: ...Connecting Other Host Systems 7 2 7017 6300 005...
Страница 169: ...Glossary 7017 6300 005 Glossary 5 U UPS Uninterruptible power supply USD Unity storage device...
Страница 170: ...Glossary Glossary 6 7017 6300 005...
Страница 175: ......
Страница 176: ...70176300 005 7 0 1 7 6 3 0 0 0 0 5...