![background image](http://html1.mh-extra.com/html/unist/4210-series/4210-series_operation-manual_3946501010.webp)
2
The Low Volume Spray Nozzle has an integral valve that maintains fluid pressure right to the tip of the nozzle, and uses
the air signal to actuate a diaphragm that operates the nozzle. This provides immediate on and off control, which
eliminates lag and prevents messy fluid drips.
Pressurize fluid is in the area highlighted in red. When the nozzle is off, the piston assembly is sealed against the
small O-ring at the tip of the nozzle. When the nozzle is on, the piston assembly is pulled away from the small O-ring,
as shown in Figures 3 and 4.
How It Works
Figure 3: Turning the Low Volume Spray Nozzle on
Figure 4: Up-close view of the piston assembly pulled
away from the small O-ring (nozzle spraying)