Zombie Night GMP Manual
03/27/2020
28
8.5 Motor Replacement Instruction
Before processing, assure you have the following tools.
No.
Name
Picture
1
Phillips screwdriver
2
Allen wrench
Step 1 Open the Bottom back door. Locate the Motor fixed plate and utilize Phillips
screwdriver to remove 4 screws.
Step 2 Pull the Motor as the big arrow’s direction to loosen the belt. Remove the Motor.
Step 3 Utilize Allen wrench to loosen 2 screws indicated by rectangles to remove
Synchronizing wheel.
Utilize Phillips screwdriver to loosen 4 screws indicated by circles to remove the plate.
Step 4 Replace with a new motor and install in reverse order. (Make sure the belt is
installed tight.)
Motor fixed plate