POWER REQUIREMENTS
The Unique UGP-120L1 W portable fridge/freezers are designed to
operate on AC and DC voltage inputs.
AC input
Voltage is required to be 110V AC at 50 - 60 Hz
DC input
Voltage is required to be 12 or 24 DC +/- 10%
AC/DC Convertor is 12V
AC POWER CONNECTION
The Unique UGP-120L1 W portable fridge/freezers are supplied with
an approved 2 pin AC power cord. It is recommended that this cord
is not lengthened as this may result in a voltage drop and reduced
performance.
DC POWER CONNECTION
EMERGENCY OVERIDE
The Unique UGP-120L1 W portable fridge/freezers are supplied with
a vehicle DC plug (cigarette lighter plug). It is recommended that
this cord is not lengthened as this may result in a voltage drop and
reduced performance.
When connecting the fridge/freezer to DC, plug the power cord into
the DC socket on the fridge/freezer and then plug the other end of
the power cord into the DC supply.
The supplied DC power cord comes with an in-line fuse. If the red
indicator light on the DC cigarette plug is not illuminated, there is
either no DC voltage being supplied or the
fuse is blown
. See below
for fuse replacement instructions.
*
Only use the DC power cord that is supplied with the fridge/freezer.
The emergency switch is located above the power inlet socket on
the side of the unit. If the digital thermostat fails and you are un-
able to set the temperature, turn this switch to Emergency override.
This enables the fridge to run until you reach a service centre to
replace the faulty component.
NOTE:
If the switch is in the “ EMERGENCY OVERRIDE” position,
the fridge/compressor will run with full cooling capacity and may
freeze. This will only freeze the zone of the fridge that is currently
turned on before flicking the emergency override switch.
Содержание UGP-120L1 W
Страница 1: ...120L 4 2 cu ft AC DC PORTABLE FRIDGE FREEZER UGP 120L1 W OWNER S GUIDE serial number JUL18V1 ...
Страница 17: ...17 UGP 120L1 W WIRING DIAGRAM ...
Страница 18: ...18 UGP 120L1 W PARTS DIAGRAM AND LIST Visit our website for full schematics ...
Страница 22: ... 2018 Unique Gas Products Ltd 2245 Wyecroft Road Oakville Ontario Canada L6L 5L7 www uniqueoffgrid com ...