15
TROUBLESHOOTING INSTRUCTIONS &
SUGGESTED SPARE PARTS TO KEEP ON HAND
REFRIGERATOR DOES NOT COOL, CHECK LIKELY CAUSES:
1.
Burner orifice clogged. Clean. See section Maintenance & Service, C
HAPTER
4,
2.
Check to ensure refrigerator is level – (left to right and front to back).
3.
Restriction on airflow across cooling unit.
4.
Heavy frost build-up on evaporator fins. Defrost.
5.
Flue baffle not inserted properly in flue tube.
6.
Improperly set thermostat. See paragraph on the thermostat. In hot weather or
heavy use the setting should be closer to “Max” than usual.
7.
Burner dirty. Clean. See Section M
AINTENANCE
&
S
ERVICE
,
C
HAPTER
4,
P
ERIODIC
M
AINTENANCE
8.
LP gas pressure low at the burner. Regulator pressure must not drop below 11
inches W.C (water column). C
HAPTER
2,
G
AS
C
ONNECTION
9.
Burner not located properly under the flue tube. Relocate; flame must be directly
into the flue
10.
Burner damaged. Replace.
11.
Odours and fumes
Dislocated burner
Damaged Burner
Dirty orifice
Dirty flue tube – C
HAPTER
4.
Chapter
5