10
OPERATING
VOLTAGE
FUSE
12 V / 24 V
15 A
DC POWER CONNECTION
continued
ATTENTION
If a longer connection cable is necessary, the cable cross section
(or gauge) must be equal to or greater than the cable sizes recom-
mended on the following table. Be careful that the input voltage at
the appliance does not drop below the cut-out voltage of the com-
pressor.
CABLE SIZE
12V CABLE
LENGTH
24V CABLE
LENGTH
AREA
AWG
mm
2
/inch Gauge
m
ft
m
ft
2.5 /
3
/
32
”
12
2.5
8
5
16
4 /
5
/
32
”
12
4
13
8
26
6 /
15
/
64
”
10
6
19.5
12
39
10 /
25
/
64
”
8
10
32.8
20
65.6
LOW VOLTAGE DISCONNECT
The compressor electronics includes a low voltage disconnect fea-
ture. If the input voltage to the appliance falls below 10.4V (in 12 V
mode) or 22.8V (in 24 V mode), the compressor will shut-off. Once
the voltage increases above 11.7V (in 12V mode) or 23.4V (in 24V
mode), the compressor will resume normal operation.
This feature is designed to protect the system battery from experi-
encing too low a depth of discharge.
12 V OPERATION
24 V OPERATION
SHUT-OFF
10.4 V
22.8 V
RESTART
11.7 V
23.4 V
REPLACING THE FUSE
Remove 3 screws from grates to access
the 15A fuse.