GAS RANGE CONVERSION (continued)
Convertible Pressure Regulator
The range is shipped to operate on LPG. NG orifices and a special screwdriver for
adjusting the minimum flame are shipped with the unit in a separate envelope with the
manual. The inlet pressure of the gas supply shall be in accordance with the nominal
inlet pressure of the regulator used on the range or 1/2 psig maximum.
The range should be tested by pressurizing the regulator with an inlet pressure at least
1 inch water column above the manufacturer’s specified manifold pressure shown on
the serial plate.
1.
CAUTION:
Before proceeding with the conversion, shut off the gas supply to the
appliance prior to disconnecting the electrical power (if applicable).
2. Locate convertible regulator at the back of the range, left side facing appliance.
Remove cap and pop out the pin that’s attached
3. On the side you will see the pin position for use with LPG
4. Unscrew pin and flip it to the NG position – long end outwards, spring on inside.
5. Below is an example of additional positions depending on regulator type installed.
9,000
3,000
9,000
10,000
13,000
44,000
9,000
3,000
9,000
10,000
13,000
44,000
Manifold Pressure:
Natural Gas: 4” WC / LP/Propane: 10” WC
Electrical Rating:
1.5V DC. 1.0 A
LPG
NG