08
The baffle may contain burnt dust and light
surface corrosion. The tip, however, must be
intact, not corroded. Soot must not be present,
as this is a sign of incomplete combustion.
Should this occur, please contact you dealer.
•
Run the brush (C9) through the flame tube. Soot must
not appear.
•
Reassemble the baffle, if necessary checking its
extension (Fig H).
•
Assemble the flue extension, making sure the wire of
the baffle fits into the slot in same.
8. Specifications
Gas Refrigerator
Outside dimensions:
•
Height
1450 mm
56 1/2”
•
Width
611 mm
24”
•
Depth
720 mm
28 1/2”
•
Open door
1270 mm
50”
Freezer capacity
31 liters
1,1 cu/ft
Refrigerator capacity
187 liters
6,7 cu/ft
Net weight
73 kg
161 lb
Weight plus packing
75 kg
165 lb
Packing volume (1470 x 652 x 762)
0,730 m
3
25,8 cu/ft
Gas consumption (high flame)
33 g/h
1600 Btu/h
Gas consumption (low flame)
14 g/h
700 Btu/h
Enclosure dimensions:
•
Height (min)
1470 mm
57 7/8”
•
Width (min)
652 mm
25 2/3”
•
Depth (max)
762 mm
30”
•
Remove the cloth from the burner and reinstall the
burner box.
Now check the operation.
•
Turn on the Refrigerator and examine the flame.
It should be sharp and blue.
•
Check the flame-failure device as indicated in item 6.3.
•
Check the union and adjacent gas fittings for leakage.
•
Turn off the Refrigerator (leaving the manual shutoff
valve open).
•
Move the Refrigerator back into is place.