background image

 

 

COPYRIGHT 2016, UNIQUE AUTOMATION 

- 8 - 

08/11/2016 12:57 

Main menu 

Access the main menu by press the menu button 

 

 

From  within  the  main  menu  using 

  / 

  buttons  select  the  option  you  wish  to 

change then use   /   to make the required change.  Confirm the choice with   
 
Main menu options: 
 

CHILD LOCK

 

Cleaning  or  child  lock.  To  unlock  the  keypad  press  and 

hold   until the display lights up. 

 

SET TEMP C/F

 

Set temperature units Centigrade or Fahrenheit 

 

ECO

 

After  a  preset  has  been  used,  when  enabled  the  true 

bath  depth  before  draining  replaces  the  prese

t’s  depth.  

You need to leave the bath and allow few seconds prior 
to draining 

Eco or Auto Learning enables  bathomatic to follow your 
preferences and/or wait and draw the perfect bath every 
time without wasting water or energy for heating it 

 

SET SLEEP TIME

 

1 or 5 minutes 

 

AUTO PAUSE

 

Allows auto-pause when there is not enough hot water 

 

T TO DEPTH WARNING

  Depth to T° warning.  When this function is ON and the 

device’s T° to depth calibration in the Service Menu has 
been  set  a  warning  message  will  appear.    When  this 
function  is  set  to  OFF  there  will  be  no  message,  but 
there  will  be  no  guarantee  of  perfect  water  depth  and 
temperature delivery   

 

TEMPERATURE PRIMING

  With this function ON bathomatic  runs water in  the bath 

at  maximum  temperature  with  open  drain.    When  the 
water  temperature  running  by  the  temperature  sensor 
reaches  the  desired  temperature  the  drain  closes  and 
normal filling proceeds.  This function should be enabled 
only when low bath depth are needed. 

 
 

To  minimise  the  environmental  impact  on  the 

TEMPERATURE  PRIMING

”  function  it  is  recommended  “

TO DEPTH CALIBRATION

 is carried out 

 
SETUP MENU 

CALIBRATION 

DEPTH CALIBRATION 

SET LEVEL 

– Allows for XXX% desired depth 

SET 0% 

– Saves 0% 

SET 100% 

– Saves 0% 

TEMP CALIBRATION 

TEMPERATURE OFFSET 

T TO DEPTH CALIBRATION 

Содержание Bathomatic Basic MK3

Страница 1: ... Basic User Interface MK3 User Guide bathomatic automated bath filler and shower control These instructions are to be left with the user COPYRIGHT 2007 2016 UNIQUE AUTOMATION ...

Страница 2: ...s 5 Running a preset 5 Changing a preset 6 Saving a preset 6 Hand Shower 7 Drain Operation 7 Closing the drain 7 Opening the drain 7 Main menu 8 Set Up Menu 10 Depth Calibration 10 Set Level 10 0 bath calibration 10 100 bath calibration 11 Temperature Offset 11 Temperature Calibration 11 Reset 11 Trouble Shooting 12 ...

Страница 3: ...ing and water temperature maintenance leaving the pleasurable part of the bathing experience bathomatic can be controlled by a range of interfaces and this guide covers the use of the bathomatic Basic User Interface BUI Below are simple instructions allowing users to run a bath and alter their preferences using the easy to navigate BUI with its function navigation buttons and graphics display Basi...

Страница 4: ... status Filling when bathomatic is filling Pause bathomatic filling draining is paused1 Draining emptying when bathomatic is draining DRAINING Empty CHOOSE TEMP DEPTH Ready READY WHEN YOU ARE Water Temperature the temperature of the water in the bath Water Depth the depth of the water in the bath Desired Temperature the temperature value last sent to bathomatic Desired Depth the depth value last s...

Страница 5: ...matic is empty and is not filling or draining Should you wish to change the desired temperature and depth when bathomatic is filling or draining press which will pause bathomatic then change the values and press and hold again for bathomatic to resume filling to the new settings Presets bathomatic stores 9 presets with individual temperature depth and fragrance selection Running a preset From the ...

Страница 6: ... back At any time you can run the altered preset without saving it just press which takes you back to the list of preset and press again for filling to take place Saving a preset Following the process above alter the variables of a preset and end the process by scrolling to the Store preset line and using store the preset or using store the preset and go back to the preset menu Temperature 38ºC Pr...

Страница 7: ...status leaving the hand shower Non active Active Drain Operation Closing the drain BUI has a dedicate drain button When the bath is empty and the drain is open pressing the button will prompt a message CLOSE DRAIN and to do this you need to press the button Opening the drain When the bath drain is closed with an empty bath or one containing water the pressing of the button will prompt a message OP...

Страница 8: ...tes AUTO PAUSE Allows auto pause when there is not enough hot water T TO DEPTH WARNING Depth to T warning When this function is ON and the device s T to depth calibration in the Service Menu has been set a warning message will appear When this function is set to OFF there will be no message but there will be no guarantee of perfect water depth and temperature delivery TEMPERATURE PRIMING With this...

Страница 9: ...ave up to two auxiliary slave BUI DEVICE TYPE a system needs one master device to operate and can have up to two slave devices ABOUT Firmware version and service contact details Exit by pressing the menu button To move back a step press the menu button also Due to a delay in your hot water delivery system there are minimum bath depths for certain temperatures3 If you are prompted with a message DE...

Страница 10: ...ct full bath depth is reached Filling does not stop automatically and can cause damage unless used correctly 0 bath calibration The easiest and fastest way for 0 bath calibration is by pouring water into the bath tub with the drain closed until the water fills the cavity of the waste completely and becomes level with the bottom of the bath tub When the water is level with the bottom of the bath tu...

Страница 11: ...he point of overflow When bathtub is at 100 depth let the water settle for 1 minute then select SET 100 in the SERVICE MENU and press to store the value Before you attempt to SET 100 you must first SET 0 It is strongly recommended that 100 bath calibration is made below the point of overflow If 100 bath calibration is set at the point of overflowing due to the fluctuation of depth reading bathomat...

Страница 12: ...c pauses on its own If the water delivered to the bath starts to decrease and the perfect bath cannot be delivered bathomatic will prompt you with WATER TEMPERATURE MAY NOT BE ACHIEVED and bathomatic will automatically go into pause Maximum water temperature during filling is 55 C ...

Отзывы: