Страница 1: ...UP 900CL 12B Digital CCD Camera User s Manual 091 0902 V 1 4 08 09 17 ...

Страница 2: ...2 Precautions 2 Limited Warranty 2 1 Introduction 3 2 Camera Setup 5 3 Camera Functions 5 4 RS 232C Communication Control 9 5 Digital Interface Timing 10 6 Camera Functional Timing 11 7 Camera Accessories 13 8 Technical Support 13 ...

Страница 3: ...ts Limited Warranty UNIQ warrants to the original customer to be free from defects in material and workmanship for two full years from the date of original purchase This warranty covers failures or damages due to defects in material or workmanship which occur during normal use It does not cover damages or failures which result from shipment mishandling abuse misuse or modification A Return Materia...

Страница 4: ...ons 1 2 Features 1 2 Progressive scan CCD imager 1392 x 1040 active pixels 12 bit RS 644 Camera Link digital output Analog output S232C interface control Full frame shutter 65 dB or better Asynchronous reset 15 Hz frame rate 25 MHz data clock C mount lens Long term frame integration External exposure control 1 3 Applications UP 900CL 12B applications include microscopy machine vision medical imagi...

Страница 5: ...ter clock Frame Rate 15 fps Sync HD 15 47KHz VD 14 82 Hz Digital Video Output Camera Link format Analog Video Output 1 V p p 75ohm BNC or 12 pin Hirose S N Ratio 65 dB Min Illumination 0 1 lux Gain MGC Gamma 1 0 Electronic Shutter 1 15 1 31 000 selectable Lens Mount C Mount Operating Temperature 10 C 50 C Power Requirement 12V DC 250mA 3 0W Dimension 50mm x 39mm x 83mm Ext Sync Internal External A...

Страница 6: ...3 1 12 Pin Connector The 12 pin Hirose connector is located on the rear panel of the camera All ground signals on pin 1 3 5 and 8 are common grounds 12 V DC input is recommended on pin 2 but this camera should withstand 12 V 1V input voltage Make sure to set the NM AM switch to NM position for external HD and VD locking Figure 2 below shows a top view of the 12 pin Hirose connector Pin No UP 900CL...

Страница 7: ...mal shutter speed make sure to set NM AM mode to NM location For asynchronous capture set NM AM mode to AM location Position No Functional Select NS Shutter Speed Select DS Shutter Speed sec NM Mode Asynchronous Capture sec AM Mode 0 Normal 1 15 Off No shutter 1 Gain Adjustment 1 30 1 60 2 Reference Adjustment 1 60 1 125 3 Factory Page 1 125 1 250 4 User Page 1 1 250 1 1500 5 User Page 2 1 500 1 1...

Страница 8: ...tings can be saved into four different user pages Once the user page is saved and set between shutter speeds 4 and 7 it will be activated as long as the camera is powered ON User Page works in both rear plate control and RS232C communication selections 3 5 Gain Control AGC MGC Manual gain control MGC MGC is standard factory setting on this camera The manual gain control can be adjusted from 9 dB t...

Страница 9: ...A3 Video LEN and FEN data output 7 20 SerTC SerTC Rx Rx Differential pair serial communications from frame grabber 8 21 SerTFG SerTFG Tx Tx Differential pair serial communications to frame grabber 9 22 CC1 CC1 HD HD Camera Control 1 CC1 Horizontal signal input 10 23 CC2 CC2 VINT VD VINT VD Camera Control 2 CC2 Vertical signal or asynchronous reset input 11 24 CC3 CC3 Reserved Reserved for custom o...

Страница 10: ... If no number entered gain will be increased by factor of 1 If a number is entered then number will be added to stored gain gd Gain decrease Hexadecimals 000 3ff Same as gi above except it will be decreased gn Gain number Hexadecimals 000 3ff Refer to the gain curves below for details bi Reference increase Hexadecimals 000 3ff If no number entered reference will be increased by factor of 1 If a nu...

Страница 11: ...10 5 Digital Interface Timing 5 1 Pixel Clock 5 2 Line Enable 5 3 Frame Enable Delay between asynchronous capture and discharge is 1H to 2H Note 1 Pixel clock 25MHz 2 1 N 40 nsec 3 H 1588 N ...

Страница 12: ...er speed position 0 15 fps 6 2 Free Run shutter speed position from 1 to F 6 3 Asynchronous Capture shutter speed position 0 6 4 Asynchronous Capture shutter speed position from 1 to E 6 5 Asynchronous Capture with Pulse Width Control shutter speed F ...

Страница 13: ...re 10 External Synchronization and Gen lock Timing 6 7 Integration via 12 pin Hirose connector ONLY The UP 900CL 12B camera can be integrated up to 2 seconds without severe noise or dark current effect To start integration pin 11 same as pin 27 of 40 pin digital connector of the 12 pin connector must be connected to GND or 0V The integrated video will be shifted out following the next vertical dri...

Страница 14: ...or UP 900CL 12B camera There are a variety of C mount lenses in the market that works with UP 900CL 12B camera Make sure the quality and specification of the lens match the camera s application Some of the most popular lenses in the market such as Cosmicar Fujinon Rodenstock and Schneider are recommended 7 3 Camera Link Cable Camera Link cable can be purchased from 3M Mouser Digi Key and frame gra...