35
5
Function Description Related to Indicated Values
35
Chapter
5
5-4.
Voltage calculation method
Set the calculation method of voltage.
<<Setting value>>
RMS:
Calculation of the RMS value of voltage by root mean square
MEAN:
RMS value of voltage is calculated by RMS value calibrated
by average rectification method.
How to set the voltage calculation method
1.
Select system setting mode.
2.
3.
Set the "Display update count".
4.
Set the "Voltage calculation method".
Press the
keys and select the
voltage calculation method (initial value:
RMS).
Press the
key to confirm and move
on to electric power measurement method.
* Press the
key to cancel the setting and move on to electric power measurement
method.
5-5.
Electric power measurement method
Set the measurement method of electric power.
<<Setting value>>
1P2:
Electric power measurement by single phase two-wire method.
3P3:
Electric power measurement by three-phase three-wire method.
How to set the electric power measurement method
1.
Select system setting mode.
2.
3.
Set the "Display update count".
4.
Set the "Voltage calculation method".
5.
Set the "Electric power measurement
method".
Press the
keys and select the
electric power measurement method (initial
value: 3P3).
Press the
key to confirm and move
on to the date and time setting.
* Press the
key to cancel the setting and move on to the date and time setting.
V
A
VA
var
W
rpm
PF
Nm
V
A
VA
var
W
rpm
PF
Nm
V
A
VA
var
W
%
PF
V
A
°C
rpm
V
°C
Nm
1
3
2
Σ
1
3
2
Σ
1
3
2
Σ
1
AUX
2
Σ
ALARM
REC
FNC
USB
RMS
MEAN
△
▽
ENT
ESC
V
A
VA
var
W
rpm
PF
Nm
V
A
VA
var
W
rpm
PF
Nm
V
A
VA
var
W
%
PF
V
A
°C
rpm
V
°C
Nm
1
3
2
Σ
1
3
2
Σ
1
3
2
Σ
1
AUX
2
Σ
ALARM
REC
FNC
USB
RMS
MEAN
△
▽
ENT
ESC
Содержание UPM100
Страница 1: ...UPM100 10JUN2015REV 1 02 POWER MONITOR OPERATION MANUAL ...
Страница 9: ...Contents VIII Contents VIII M E M O ...
Страница 78: ...69 9 Specifications 69 Chapter 9 9 2 External dimensions Unit mm 㸦 r 㸧 㼃㼔㼑㼚㻌㼡㼟㼕㼚㼓㻌㼍㻌㼟㼠㼍㼚㼐 ...
Страница 89: ......