7.FUNCTION AS A WEIGHT CHECKER
53
7-3-2. Near zero comparison/ Near zero
1) NEAR ZERO COMPARISON
Select the weight value to make NEAR ZERO COMPARISON.
Select from GROSS/ NET/ COMPARISON OFF/
ABSOLUTE GROSS/ ABSOLUTE NET.
GROSS
Comparison is made by gross.
NET
Comparison is made by net.
COMPARISON OFF
Comparison is not made.
ABSOLUTE GROSS
Comparison is made by absolute-value gross.
ABSOLUTE NET
Comparison is made by absolute-value net.
2) NEAR ZERO
Set the near zero comparison weight value.
(input range: 0 ~ 99999)
Operation
7-3-3. Over/Under comparison 1
Select the weight value to make OVER/UNDER COMPARISON.
Select from GROSS/ NET/ COMPARISON OFF.
GROSS
Comparison is made by gross.
NET
Comparison is made by net.
COMPARISON OFF
Comparison is not made.
Operation
7-3-4. Complete output time
Set the length (time) of outputting the COMPLETE signal (pin 24 of the control connector) upon
completion of weighing.
(input range: 0.0 ~ 9.9)
Operation
MODE
COMPARISON
→
Press
NEAR ZERO COMPARISON
→
Select GROSS/ NET/ COMPARISON OFF/
OK
→
1)
→
ABSOLUTE GROSS/ ABSOLUTE NET
MODE
COMPARISON
→
Press
NEAR ZERO
→
2)
→
Input 0 ~ 99999
OK
→
MODE
COMPARISON
→
Press
OVER/UNDER COMPARISON 1
→
→
Select GROSS/ NET/ COMPARISON OFF
OK
→
MODE
COMPARISON
COMPLETE OUTPUT TIME
→
Press
→
Input 0.0 ~ 9.9
OK
→
→
Содержание F805AT-CK