6.FUNCTION SETTING
40
6-1-6. Digital zero
The Digital Zero function zeroes the Gross Weight to adjust for slight shifts at the zero point due to
load cell drift or dregs remaining on a scale.
If Digital Zero is operated when the displayed weight is beyond the set Digital Zero Regulation Value
(Refer to on Page40), then the Zero Alarm is actived,
appears red.
Operation
Display
on the comparison screen then
press
.
To operate Digital Zero via the Control connector on the rear panel, input ON edge signal to the pin 3
(D/ Z ON) and the COM (Common).
6-1-7. Digital zero clear
When
highlights in red, do Digital Zero Clear.
Then Digital Zero will be cleared and
goes out.
Operation
Input PASSWORD 1269
→
1111 in order.
6-1-8. Digital zero regulation value
Set a range for Digital Zero adjustment (a gap from the Registered Zero Calibration) by operating
Digital Zero or Zero Tracking.
Operation
ZALM
GROSS
DZ
★
★
Digital Zero ON
Digital Zero ON
★
Pulse width: 50ms or more
External input
(pin 3)
ZALM
ZALM
MODE
PAGE
→
→
Press
SYSTEM
→
Input 1269
OK
→
PASSWORD
→
PASSWORD
→
→
Input 1111
OK
→
MODE
OPERATION
PAGE
→
→
Press
DZ REGULATION VALUE
→
→
Input 0 ~ 9999
OK
→
Содержание F805AT-CK
Страница 1: ...F805AT CK CHECKER SCALE CONTROLLER OPERATION MANUAL 01 Sep 2022 Rev 1 05...
Страница 129: ......