6.SETTING AND ADJUSTMENT OF READING
63
6-4-7. Weight density over
Over scale alarm “OFL2” is activated when weight density becomes greater than
WEIGHT DENSITY OVER set value. Comparison is disabled if the value is set to
99999. Also, the comparison is disabled if [WEIGHT DENSITY OVER OVER ASC.]
is set to zero second.
Operation
6-4-8. Feed rate over
Over scale alarm “OFL3” is activated when the feed rate becomes greater than FEED
RATE OVER set value. The unit for this value is either kg/h or t/h depending on the
selection in [FEED UNIT]. Comparison is disabled if the value is set to 99999. Also,
the comparison is disabled if [FEED RATE OVER ASC.] is set to zero second.
Operation
6-4-9. Load ratio over
Over scale alarm “OFL4” is activated when the load ratio becomes greater than LOAD
RATIO OVER set value. Comparison is disabled if the value is set to 999.99. Also, the
comparison is disabled if [LOAD RATIO OVER ASC.] is set to zero second.
Operation
Range: 0 – 99999 kg/m (5 digits, decimal place floating)
MODE
COMPARISON
→
→
WEIGHT DENSITY OVER
MODE
COMPARISON
→
→
FEED RATE OVER
Range: 0 – 99999 (5 digits, decimal place floating)
PAGE
→
Range: 0 – 999.99 % (5 digits, decimal place fixed)
MODE
COMPARISON
→
→
LOAD RATIO OVER
PAGE
→