6.SETTING AND ADJUSTMENT OF READING
48
6-1-7. Dead band load ratio
While the value of DEAD BAND LOAD RATIO (%) is greater than LOAD RATIO
(%), F805AT-BC turns on “NZ” status indicator and set the NZ external signal to
“ON”. Accumulation is not performed in this state. Setting DEAD BAND LOAD
RATIO to zero disables accumulation calculation.
Operation
6-1-8. Dead band belt speed
F805AT-BC performs arithmetic calculations assuming the belt speed to be 0.00 m/min
if:
Belt speed [m/min] < Rated belt speed [m/min] × Dead band [%]/100
Operation
6-1-9. Moisture ratio
This parameter specifies the moisture content (%) of the material to be conveyed.
Moisture is excluded from accumulation calculation. This value does not affect weight
density, feed rate, load rate, and feed ratio measurements.
Operation
Input Range: 0 – 99 % (2 digits)
MODE
OPERATION
DEAD BAND LOAD RATIO
→
→
Input Range: 0 – 99 % (2 digits)
MODE
OPERATION
DEAD BAND BELT SPEED
→
→
Input Range: 0 – 99 % (2 digits)
MODE
→
MOISTURE RATIO
PAGE
OPERATION
→
→