1.FEATURES OF F805AT-BC (BELT SCALE TYPE)
3
1-4. RS-232C, RS-485 (RS-485 optional)
Most of the set values, and most of the calculation results and device status information
can be read/written using the serial communication.
1-5. Current Outputs (2 channels) and Pulse Input (DAC)
The output mode for two current output channels can be separately selected from fixed
span mode (4mA or 20mA), or mathematical calculation dependent mode (belt speed,
weight density, feed rate, load ratio, feed ratio, control rate).
Pulse signal from the velocity detector can be used as the belt speed signal in
calculations.
1-6. Analog Inputs (2 channels) and Current Outputs (3 channels)
(ANA optional)
The output mode for three current output channels can be separately selected from
fixed span mode (4mA or 20mA), or mathematical calculation dependent mode (belt
speed, weight density, feed rate, load ratio, feed ratio, control rate).
Analog signal from the velocity detector (current, or voltage) can be used as the belt
speed signal in calculations.
Pulse signal from the velocity detector can be used as the belt speed signal in
calculations.
1-7. BCD Input/Output (BCI and BCO optional)
Alarm upper/lower limits, rated belt speed, and moisture ratio can be configured using
the BCD input.
BCD output can be used to send out following values: belt speed, weight density, feed
rate, load ratio, feed ratio, and total.
1-8. Upper/Lower Limit Comparison
Either load ratio or feed ratio is compared with its upper/lower limit, and the current
status is displayed and sent to the external output.
1-9. Total Pulse Output (2 channels)
One of two types of Total pulse outputs can be selected depending on the feed pulse
(W/P) and the pulse width settings.