7.CONTROL SIGNAL (External I/O Connector)
95
7. CONTROL SIGNAL (External I/O Connector)
F805AT-BC uses a 50-pin amphenol connector for input/output of external signals. The
F805AT-BC compatible plug is DDK 57-30500 (supplied) or its equivalent.
7-1. Pin Assignment
* COM: following pins are connected together inside the instrument: 1, 10, 15, 16, 25,
26, 35, 40, 41, and 50.
* Supply voltage is not available from this terminal.
1
*
COM
26
*
COM
2
IN
RUNNING
27
IN
DZ
3
IN
DISP1 CHANGE1
28
IN
ZERO POINT
AUTO ADJUSTMENT
4
IN
DISP1 CHANGE2
29
IN
TEST MODE
SPAN MEASUREMENT
5
IN
DISP1 CHANGE4
30
IN
PULSE COUNT START
6
IN
DISP2 CHANGE1
31
IN
PULSE COUNT STOP
7
IN
DISP2 CHANGE2
32
IN
OPERATION MODE 1
8
IN
DISP2 CHANGE4
33
IN
OPERATION MODE 2
9
IN
T.WT.CLEAR
34
IN
GRAPH DRAWING
10
*
COM
35
*
COM
11
IN
CODE# DESIGNATION1
36
IN
CODE# DESIGNATION10
12
IN
CODE# DESIGNATION2
37
IN
CODE# DESIGNATION20
13
IN
CODE# DESIGNATION4
38
IN
CODE# DESIGNATION40
14
IN
CODE# DESIGNATION8
39
IN
CODE# DESIGNATION80
15
*
COM
40
*
COM
16
*
COM
41
*
COM
17
OUT
PULSE OUTPUT1
42
OUT
RUNNING
18
OUT
PULSE OUTPUT2
43
OUT
NZ
19
OUT
UPPER LIMIT(HI)
44
OUT
TOTAL FINAL OVER
20
OUT
GO
45
OUT
ZERO ERR. MEASURING
21
OUT
LOWER LIMIT(LO)
46
OUT
ZERO ERR. MEAS. OK
22
OUT
WEIGHT ERROR
47
OUT
ZERO ERR. MEAS. NG
23
OUT
BELT MOVING
48
OUT
FEED RATE OVER
24
OUT
POWER ON
49
OUT
FEED RATE UNDER
25
*
COM
50
*
COM