1.APPEARANCE DESCRIPTION
3
See the section on Load Cell Connection page 10 for connection.
See the section on External I/O Connection page 12 for connection.
See the section on External I/O Connection page 12 for connection.
See the section on SI/F Connection page 11 for connection.
+EXC
-EXC
+SIG
-SIG
The terminal for connecting to a strain-gage sensor.
COM1
The terminal common to output signals.
OK
HI
LO
HH
LL
Outputs the OK signal.
Outputs the HI signal.
Outputs the LO signal.
Outputs the HH signal.
Outputs the LL signal.
H/E
Outputs the hold end signal.
COM2
The terminal common to input signals.
CODE0
CODE1
CODE2
CODE3
Selects the CH No. for the multi-hold function.
→
T/H
H/M
D/Z
The input for digital zero (making the indicated value zero).
→
ST/SP
The graphic display start/stop signal.
SI/F
The 2-wire serial interface for coupling a UNIPULSE printer,
external display, etc.
「
→
The input for controlling the hold signal.
→
Caution
Use TMEV1.25-3S crimp contacts (attached) made by NTM or
equivalent for connection to the signal I/O terminal block and the
AC power source input terminal block.