1FUNCTIONAL DESCRIPTIONS
6
1-2-4. AC Power Input Terminal Block
Connect AC power code. The input voltage is 100V to 240V AC.
The frequency is 50/60Hz.
1-2-5. Signal Input/Output Terminal Block
This terminal block is used for input/output of control signals and input of strain
gauge sensor signals.
• Terminal block Assignment
A1-A4
:
Output terminals of the high/low limit relays.
(rating; 250V AC 0.5A)
A1
High limit relay
(
N/O
)
A2
High limit COM
A3
Low limit relay
(
N/O
)
A4
Low limit COM
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
N/O
COM
N/O
COM
F.G.
High limit relay Low limit relay
DZ
input
COM HOLD
input
Analog
monitor
output
Analog
COM
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
L
N
F.G.
A-
B+
S.G.
+EXC
-SIG
-EXC
+SIG
AC power input
RS-485
Strain gauge
sensor input
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
Содержание F320