50
7
OPTION (Setting Code 38)
50
OP
TION
Chapter
7
- Connector pin assignments for binary output: FCN-365P032-AU/FCN-360C032-B
Currently-selected data can be confirmed by B8 and B9.
For the BCD output data list, refer to "
BCD Output Data List" on page 50.
Output signal selection
Any one of the following output signals can be assigned to B12.
Setting/
0: Near zero
1: Stable
2: Weight alarm
3: Sequence error
4: Final error
5: Zero alarm
■
BCD Output Data List
When the BCD output data selection is set to "External selection," switch data by A15 and B15.
*1: BCD data switch input condition when the BCD Output Data Selection is "External selection".
■
Logic Switching
Switch the logic of output signals with pin B14.
When COM and pin B14 are open: negative logic, When they are short-circuited: positive logic.
A1
-
COM
COM
-
B1
A2
OUT
2
0
2
12
OUT
B2
A3
OUT
2
1
2
13
OUT
B3
A4
OUT
2
2
2
14
OUT
B4
A5
OUT
2
3
2
15
OUT
B5
A6
OUT
2
4
2
16
OUT
B6
A7
OUT
2
5
OUT
B7
A8
OUT
2
6
BCD Data Switch 0 (Response)
OUT
B8
A9
OUT
2
7
BCD Data Switch 1 (Response)
OUT
B9
A10
OUT
2
8
Minus (Polarity)
OUT
B10
A11
OUT
2
9
OVER
OUT
B11
A12
OUT
2
10
Output Signal Selection
OUT
B12
A13
OUT
2
11
STROBE
OUT
B13
A14
IN
BCD Data Hold
Logic Switch
IN
B14
A15
IN
BCD Data Switch 0
BCD Data Switch 1
IN
B15
A16
-
-
B16
BCD data switch 1
*1
BCD data switch 0
*1
Output data
OFF
OFF
Gross weight
OFF
ON
Net weight
ON
OFF
Tare weight
ON
ON
Gross weight
Содержание F160
Страница 1: ...01AUG2017REV 1 06 WEIGHING CONTROLLER F160 CC Link Ver 1 10 OPERATION MANUAL...
Страница 9: ...CONTENTS VIII CONTENTS VIII M E M O...
Страница 84: ...75 8 SPECIFICATIONS 75 SPECIFICATIONS Chapter 8 Equipped with BCD parallel data output interface option Unit mm...
Страница 85: ...76 8 SPECIFICATIONS 76 SPECIFICATIONS Chapter 8 Equipped with CC Link interface option Unit mm...
Страница 99: ......