FUNCTIONS
41
FUNCTIONS
Chapter
5
■
Sequence with Adjust Feeding Valid
●
Set adjust feeding ON/OFF in the sequence mode of setting code 51 to ON.
●
The complete signal output timing depends on the setting of the complete output mode of setting
code 26.
●
Over/Under comparisons are made, holding the weight value, when the complete output is ON,
deregarding the setting of Over/Under comparison mode of setting code 27.
●
Upper/Lower limit comparisons are always made deregarding the setting of the Upper/Lower
limit comparison mode of setting code 28.
t1: Comparison inhibit time; comparison inhibit time of setting code 10
t2: Judging time; judging time of setting code 11
t3: Complete output time; complete output time of setting code 12
t4: Adjust feeding time; adjust feeding time of setting code 13
Adjust feeding time (Setting code 13)
S
et the adjust feeding time.
Setting range/
000 to 999
Initial value/
100
Adjust feeding at the sequence mode (Setting code 51)
Determines whether adjust feeding is valid or invalid.
Setting/
0: Invalid
1: Valid
Start
Stop
SP1
SP2
SP3
ON
ON
ON
ON
OFF
t1
Complete
Comparison inhibit time
Complete output time
t3
t1
t2
t2
t4
Hold
Judgment (Over or Go)
Judging time
Adjust feeding time
ON
ON
Содержание F160
Страница 1: ...01AUG2017REV 1 06 WEIGHING CONTROLLER F160 CC Link Ver 1 10 OPERATION MANUAL...
Страница 9: ...CONTENTS VIII CONTENTS VIII M E M O...
Страница 84: ...75 8 SPECIFICATIONS 75 SPECIFICATIONS Chapter 8 Equipped with BCD parallel data output interface option Unit mm...
Страница 85: ...76 8 SPECIFICATIONS 76 SPECIFICATIONS Chapter 8 Equipped with CC Link interface option Unit mm...
Страница 99: ......