3.2. Wiring diagrams 

3.2.1. Using as a relay (dry contact) and/or monitored input - check for short circuit  

1

2

3

4

5

6   7  8

E +

-   -

+ E

10k

Ω

N

NO

O

10k

Ω

IN

Address Loop

C   

NO

  

NC

9 10 11 12 13 14

RELAY

check for short circuit of the input andmanaging

of external device through reley 

with non-potential contacts

1

2

3     4

5

6    7

8

E    +     -     -     +    E

10k

Ω

NC

IN

Address Loop

C   

NO

  

NC

9 10 11 12  13 14

RELAY

1      2     3      4      5     6      7     8

E    +     -     -     +    E

10k

Ω

NC

IN

Address Loop

 9 10 11 12

5,6k

Ω

1N4001

-

 

Out +

+

-

-

   

13 

5

1

1

16 

28V

does not check for short circuit of the input and

managing of external device through reley 

with non-potential contacts

3.2.2 Using as a monitored output or monitored (technical common) input

1      2     3      4 

5   6      7   8

E    +     -     -     +    E

10k

Ω

N

NO

O

10k

Ω

IN

Address Loop

 9 10 11 12

5,6k

Ω

1N4001

-

 

Out +

+

-

-

   

13 

5

1

1

16 

28V

check for short circuit of the input and

managing of external device through monitored output

does not check for short circuit of the input and

managing of external device through monitored output

Fig.3A

Fig.3B

Fig.3C

Fig.3D

Manufacturer: UniPOS Ltd., 47 San Stefano Street, Pleven 5800, Bulgaria,

 http://www.unipos-bg.com

09/09.19

Содержание FD7203

Страница 1: ... built inon the device PCB pos 1 fig 1 illuminated in yellow and red pos2 fig 1 light providing device status information 1 2 3 4 5 6 7 Fig 1 Picture of input output module Теchnical Data Аddressable loop supply voltage 15 30 Vdc current consumption in duty mode 350µA current consuption in alarm state 2 1 mA Input 1 pc Fault condition interruption Rline 25kΩ Fault condition short circuit Rline 2 2...

Страница 2: ...cted in according to step 3A then the module will enter in Duty mode In order to learn the new configuration it is required to press and hold for 5 second the tactile button fig 3 step 5 In case that operation is successfully done the module red LED indication will be activated in the left site of the module PCB fig 3 step 5 the module enter in service system mode The module will not communicate w...

Страница 3: ...Фиг 3 Manufacturer UniPOS Ltd 47 San Stefano Street Pleven 5800 Bulgaria http www unipos bg com 09 09 19 ...

Страница 4: ... circuit switched OFF fig 2 and wires are connected in according to fig 3B and 3D the panel does not check monitor for fault short circuit Important note Activation of the input is done through non potential contact dry contact 3 1 3 Output and external power supply Terminals from 9 to15 depends from configurating of the type output fig 2 and fig 3A or 3B or 3C or 3D 3 1 3 1 Output configured as m...

Страница 5: ...01 Out 13 5 1 4 1 16 28V does not check for short circuit of the input and managing of external device through reley with non potential contacts 3 2 2 Using as a monitored output or monitored technical common input 1 2 3 4 5 6 7 8 E E 10kΩ N NO O 10kΩ IN Address Loop 9 10 11 12 5 6kΩ 1N4001 Out 13 5 1 4 1 16 28V check for short circuit of the input and managing of external device through monitored...

Страница 6: ...bserved The manufacturer does not bear warranty liabilities for damages caused through accidental mechanical damage misuse adaptation or modification after production Accessory installation of a modular box cabinet For the In Out module 7203 IO type is available accessory a modular box consisting of the module cabinet The accessory is used to bind to cover the cables to the connection terminals Un...

Отзывы: