![Union Community VIRDI-4000 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/union-community/virdi-4000/virdi-4000_installation-manual_843001005.webp)
5
Installation for VIRDI-4000
V3.2
3. Main Board Feature
3. Main Board Feature
J101 Wiegand IN/Out
:
1 : Wiegnad IN 0 ( Brown )
2 : Wiegand IN 1 ( Red )
3 : Wiegand Out 0 ( Orange )
4 : Wiegand Out 1 ( Yellow )
5 : Ground ( Black )
J301 Keypad Interface
J501 Ethernet
J101 Wiegand IN/OUT
SW2 Lock Type Switch
Lock 1
Lock 2
Input 1
Input 2
RS485B
RS485A
DC12V
GND
F.GND
GND
Exit Button
: Lock Control Output
: Lock Control Output
: Door Monitor Input 1
: Door Monitor Input 2
: RS-485 B
: RS-485 A
: DC 12V Input
: DC Input Ground
: Field Ground
: Inside Open GND
: Inside Open Exit Button
SW201,204 Lock Type Switch
SW202,203 Lock Type Switch
F251 Fuse
J302 Fingerprint Sensor
SW2 Dip Switch
: Default Setting =>3:ON
1 : Option ( RS485 Product ID )
2 : Option ( RS485 Product ID )
3 : Motor (on) / Strike (off) Select
4 : Reserved
5 : Reserved
6 : Reserved
Switch Setting
II
[ Lock Type Selection ]
SW201 : NO [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
SW202 : ST/M [ Strike/Motor/Dead-Bolt Lock ]
A/D [ Auto Door Selection ]
SW203 : Strike [ Strike, Auto Door, Dead bolt ]
Motor [ Motor Lock Selection ]
SW204 : ST/M [ Strike/Motor/Dead-bolt Lock ]
A/D [ Auto Door Selection ]
SW102 RS485 Termination
Resistor Select Switch
J251 5V Output
SW101 RS232 Level Select
Switch Setting
I
[ RS-232 Level Selection ]
SW101 : Default Setting =>1,4 :ON
Serial0 => 232 Driver Level : 1:ON, 2:OFF
232 TTL Level : 1:OFF, 2:ON
Serial1 => 232 Driver Level : 3:ON, 4:OFF
232 TTL Level : 3:OFF, 4:ON
Switch Setting
III
[ RS485 T_Resistor Selection ]
SW201 : ON [ 120ohm termination resistor ]
OFF [ Open the termination resistor ]
RV201 Volume Control