  Servicing of batteries should be performed or supervised by personnel 

knowledgeable  of  batteries  and  the  required  precautions.    Keep 
unauthorized personnel away from batteries.

 

  When replacing  batteries, replace with the same  type and number of 

the  sealed  lead-acid  batteries.  The  maximum  ambient  temperature 
rating is 40

  This pluggable type A equipment with battery already installed by the 

supplier is operator installable and may be operated by laymen. 

  During the installation of this equipment it should be assured that the 

sum  of  the  leakage  currents  of  the  UPS  and  the  connected  loads 
does not exceed 3.5mA. 

  Attention,  hazardous  through  electric  shock.  Also  with  disconnection 

of this unit from the mains, hazardous voltage still may be accessible 
through  supply  from  battery.  The  battery  supply  should  be  therefore 
disconnected  in  the  plus  and  minus  pole  of  the  battery  when 
maintenance or service work inside the UPS is necessary. 

  The mains socket outlet that supplies the UPS shall be installed near 

the UPS and shall be easily accessible.

 

 

Wichtige Sicherheitshinweise 

Bitte lesen Sie diese Hinweis sorgfaltig durch. 

  Vor  jedem  rcinigen  ist  das  Ger

ä

t  vom  Stromnetz  zu  trennen. 

Verwenden  Sie  Keine  Fl

üssig-oder  Aerosolreiniger.    Am  besten 

eignet sich ein angefeuchtetes Tuch zur Reinigung. 

 

Das Gerät ist vor Feuchtigkeit zu schützen.

 

 

Ö ffncn  Sie  niemals  das  Gerät.  Das  Gerät  darf  aus  Gründen  der 

elektrischen  Sicherheit  nur  von  authorisicrtem  Servicepersonal 
geöffnct Wcrdcn.

 

 

Bei der Installation is darauf zu achten, das der  Gesamtableitstrom 
der  USV  und  der  and  der  USV  angeschlossenen  Verbraucher  den. 

Maximalwert von 3.5mA nicht überschreiten.

 

 

VORSICHT:  Explosionsgetahr  bei  unsachgemäßen  Austausch  der 
Batterie.  Ersatz  nur  durch  denselben  order  einem  vom  Hersteller 
empfoblenem ähnlichen Typ. Entsorgung gebrauchter Batterien nach 
Angaben des Herstellers.

 

 
 

Содержание 400

Страница 1: ...USER MANUAL Line Interactive UPS Uninterruptible Power System ...

Страница 2: ...FETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for models Line Interactive 400 600 and 800 that should be followed during installation and maintenance of the UPS and batteries ...

Страница 3: ...cessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit...

Страница 4: ...cted in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible Wichtige Sicherheitshinweise Bitte lesen Sie diese Hinweis sorgfaltig durch Vor jedem rcinigen ist das Gerät vom Stromnetz zu trennen Verwenden Sie Keine Flüssig oder Aerosolreiniger ...

Страница 5: ...s monitor UPS inside status The main features of the UPS are listed below Microprocessor control guarantees high reliability Equipped with Boost and Buck AVR Built in RS 232 Communication Port Free Software Download from the Internet Please check Free Software Download in Installation Operation for detail information Green Power Function for energy saving DC Start Function Auto restart while AC re...

Страница 6: ...plugged in for at least 8 hours with no load no electrical devices such as computers monitors etc connected 3 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other ha...

Страница 7: ...unction This UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode 8 Free Download Software WinPower Go to the website http www ups software download com winpower htm Choose the operation system you need and follow the instruction described on the website to download the software When downloading all ...

Страница 8: ...ption Front panel 1 Power Switch 2 LED Indicators AC Mode Green lighting Battery Mode Green flashing Back Panel 1 Output receptacles 2 AC input with AC fuse 3 Modem Phoneline Surge Protection 4 USB Communication Port ...

Страница 9: ...capability specified in the specs When power failure back up time is shorten 1 Overload of the UPS 1 Remove some noncritical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal but LED is flashing 1 Fuse is blown 1 Replace the same type...

Страница 10: ...tor 12 minutes 23 minutes 34 minutes Recharge Time 8 hours to 90 after complete discharge TRANSFER TIME Typical 2 6 ms INDICATOR AC Mode Green lighting Backup Mode Green flashing AUDIBLE ALARM Backup Mode Sounding every 10 seconds Low Battery Sounding every second Overload Sounding every 0 5 second Battery Replacement Sounding every 2 seconds Fault Continuously sounding PROTECTION Full Protection ...

Отзывы: