When the overload protection is working, the air flow from the unit will be at the ambient temperature 

of the room, but will not cool the air. 

If overload protection works frequently, find out, and fix the problem before using the unit.

Please adjust the angle of the cooling duct and heating exhaust duct before using the unit. Hold the 

curved duct and bend the cooling duct for angle adjustment.

 

COMPRESSOR OVERLOAD / OVERHEAT  PROTECTION

   If the compressor overheats or overloads due to high or low voltage or high ambient temperature, 
   the built in safety protection for the compressor will start working and turn off the unit. 

 

ADJUSTING THE AIR FLOW DIRECTION.

  Please adjust the duct to get the desired cooling and heating direction. The cooling duct adjustment 
  range is 200° horizontal and 50° vertical. The heat exhaust duct adjustment range is 40°.

NOTIFICATION

NOTIFICATION

 

KEEP DISTANCE

  Make sure the unit has minimum distance from any wall, ceiling, or object as illustrated below.
  In order to prevent accidents, the unit should be placed on level ground. Unlevel ground, stairs, 

  emergency exits should not be used. 

  Minimum distance needed is 12” from any wall. While the unit operates, please do not place 

  obstructions in front of the filter, cooling, or heating exhaust duct.

Heating Outlet

Direction above 

32”

Air Intake

Direction above 

12”

Cooling Outlet

Direction above 

12”

Содержание KoolBase MSC407NE

Страница 1: ...USER MANUAL MSC407NE KoolBase MOBILE SPOT COOLER ...

Страница 2: ...THANK YOU FOR PURCHASING THE KOOLBASE MOBILE SPOT COOLER PLEASE READ THE INSTRUCTIONS BEFORE USING KEEP THESE INSTRUCTIONS FOR REFERENCE KoolBase 2 ...

Страница 3: ...TY PRECAUTIONS PAGE 4 5 2 SPECIFICATIONS PAGE 6 3 ACCESSORIES PAGE 6 4 PARTS OF THE MACHINE PAGE 7 5 INSTALLATION PAGE 7 6 OPERATING INSTRUCTION PAGE 8 7 MAINTENANCE AND INSPECTION PAGE 11 8 TROUBLESHOOTING PAGE 12 KoolBase 3 ...

Страница 4: ...er gasoline kerosene LPG aluminum magnesium and plumbum They could cause possible fire or explosion Only a professional repair service should disassemble the unit in order to avoid warranty voidance or safety issues such as fire electric shock and injury If you need repairs please contact the manufacture or qualified repair service This mark stands for under any circumstances this unit should not ...

Страница 5: ...nge from 64 F to 104 F otherwise it may cause the unit to slow the air flow or shutdown To prevent an accident or damage the unit can not be used in the following locations Not grounded Unlevel ground Stairs emergency exit or entrance Area of strong wind heavy dust or metal powder Unplug unit for repair or installation Do not bend pull bind clip or change the power cord It may cause accidents such...

Страница 6: ...ling Duct Drain Hose Heat Exhaust Duct REFRIGERANT RATED CHARGE WATER STORAGE CAPACITY CONDENSATE WATER HANDLING METHOD SIZE WEIGHT OPERATING TEMPERATURE LIMIT Single Phase 115 V 60 Hz High 8 8 A 1050 W Low 7 9 A 950 W 8 500 BTU Fully Closed Type Rotary R410 A 440 g 4 L Condensation Tank Drain Pipe 15 17 31 81 6 LB 77 113 KoolBase 6 ...

Страница 7: ...wn until curved duct clicks in place It will rotate 360 INSTALLING THE COOLING DUCT Slide the cooling duct raised nub in to the slot of the curved duct Then turn clockwise to lock Make sure the duct is connected properly before using When adjusting the direction turn the curved duct instead of the cooling duct KoolBase 7 Raised Nub Slot Curved Duct Cooling Duct Cold Air Exit Cooling Duct Installat...

Страница 8: ...ng High Cooling High Fan To power on turn on the switch at the top of the unit to either low or high fan or low or high cooling for operation There are 4 options 1 Low Fan Light air flow at ambient temperature 2 High Fan Strong air flow at ambient temperature 3 Low Cooling Sends a flow of cold air at low fan speed 4 High Cooling Sends a flow of cold air at high fan speed Operating temperature is b...

Страница 9: ... compressor will start working and turn off the unit ADJUSTING THE AIR FLOW DIRECTION Please adjust the duct to get the desired cooling and heating direction The cooling duct adjustment range is 200 horizontal and 50 vertical The heat exhaust duct adjustment range is 40 NOTIFICATION NOTIFICATION KEEP DISTANCE Make sure the unit has minimum distance from any wall ceiling or object as illustrated be...

Страница 10: ...Line Condensation Tank 5L Drain Tank Using Hose Connection Included Hose Hole Manual Extraction CASTER WHEEL LOCK UNLOCK The front wheels come with locks For safety lock the casters and check the unit for movement KoolBase 10 Please check the amount of the water periodically Drain the water before moving the unit Empty the water immediately when the water gets to the red line The unit does not hav...

Страница 11: ...r with heavy use consider vacumming filter before rinsing Rinse with water and dry thoroughly before reuse When cleaning the surface of the unit do not use abrasive materials or chemicals which could damage the unit surface Please clean the filter regularly NOTIFICATION ...

Страница 12: ...he drain pipe Clean the filter Remove tank and empty the water Clean the condensor surface and vents Check fan Move to more a suitable place to use Check the capacitor to the compressor Check pipeline system and clean Check for proper voltage Insert the plug into the wall outlet Check breaker on main panel and reset Ask the technical service department for assistance The warranty period of this ma...

Страница 13: ...CATED OUTLET DO NOT SHARE AN OUTLET WITH OTHER DEVICES SHARING AN OUTLET MAY CAUSE A POWER OUTAGE 2 IF USING AN EXTENSION CORD A 12 AWG IS RECOMMENDED 3 DO NOT BLOCK THE HEAT EXHAUST DUCT BLOCKING THE HEAT EXHAUST COULD CAUSE THE UNIT TO OVERHEAT AND STOP WORKING PROPERLY ...

Страница 14: ... KoolBase 14 OPTIMUM OPERATING TEMPERATURE RANGE FOR KOOLZONE MOBILE SPOT A C COOLER IS FROM 64 104 FAHRENHEIT WHEN USING THIS UNIT ON COOLING MODE THE AMBIENT TEMPERATURE WILL BE REDUCED BETWEEN 10 15 FAHRENHEIT ...

Страница 15: ...KoolBase ...

Отзывы: