Unimig RAZOR CUT 45 Скачать руководство пользователя страница 3

3

RAZOR CUT 45 AIR COMPRESSOR

OPERATING MANUAL

1. Safety

Welding and cutting equipment can be dangerous to both the operator and people in or near the surrounding working 
area if the equipment is not correctly operated. Equipment must only be used under the strict and comprehensive 
observance of all relevant safety regulations.

Read and understand this instruction manual carefully before the installation and operation of this equipment.

Machine operating safety   

•  Do not switch the function modes while the machine is operating. Switching of the function modes during welding can 

damage the machine. Damage caused in this manner will not be covered under warranty.

•  Disconnect the electrode-holder cable from the machine before switching on the machine, to avoid arcing should the 

electrode be in contact with the workpiece.

•  Operators should be trained and or qualified.

Electric shock: it can kill

•  Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live 

whenever the output is on. The input power circuit and internal machine circuits are also live when power is on. In MIG/
MAG welding, the wire, drive rollers, wire feed housing, and all metal parts touching the welding wire are electrically live. 
Incorrectly installed or improperly grounded equipment is dangerous.

•  Connect the primary input cable, according to Australian and New Zealand standards and regulations.
•  Avoid all contact with live electrical parts of the welding/cutting circuit, electrodes and wires with bare hands.
•  The operator must wear dry welding gloves while he/she performs the welding/cutting task.
•  The operator should keep the workpiece insulated from himself/herself.
•  Keep cords dry, free of oil and grease, and protected from hot metal and sparks.
•  Frequently inspect input power cable for wear and tear, replace the cable immediately if damaged, bare wiring is dangerous 

and can kill.

•  Do not use damaged, undersized, or badly joined cables.
•  Do not drape cables over your body.
•  We recommend (RCD) safety switch is used with this equipment to detect any leakage of current to earth.

Fumes and gases are dangerous

•  Smoke and gas generated while welding or cutting can be harmful to people’s health. Welding produces fumes and gases. 

Breathing these fumes and gases can be hazardous to your health.

•  Do not breathe the smoke and gas generated while welding or cutting, keep your head out of the fumes.
•  Keep the working area well ventilated, use fume extraction or ventilation to remove welding/cutting fumes and gases.
•  In confined or heavy fume environments always wear an approved air-supplied respirator.
•  Welding/cutting fumes and gases can displace air and lower the oxygen level, causing injury or death. Be sure the breathing 

air is safe.

•  Do not weld/cut in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with 

vapours to form highly toxic and irritating gases.

•  Materials such as galvanised, lead, or cadmium plated steel, containing elements that can give off toxic fumes when welded/

cut. Do not weld/cut these materials unless the area is very well ventilated, and or wearing an air-supplied respirator.

Arc rays: harmful to people’s eyes and skin

•  Arc rays from the welding/cutting process produce intense visible and invisible ultraviolet and infrared rays that can burn 

eyes and skin.

•  Always wear a welding helmet with the correct shade of filter lens and suitable protective clothing, including welding gloves 

while the welding/cutting operation is performed.

•  Measures should be taken to protect people in or near the surrounding working area. Use protective screens or barriers to 

protect others from flash, glare and sparks; warn others not to watch the arc.

Содержание RAZOR CUT 45

Страница 1: ...CUT45 U14007 Operating Manual...

Страница 2: ...ESSOR OPERATING MANUAL 1 Safety 3 2 Package Contents 6 3 Compressor Specifications 7 4 Compressor Layout 8 4 1 Front Panel Layout 8 4 2 Rear Panel Layout 8 4 3 Air Regulator Layout 8 5 Machine Setup 9...

Страница 3: ...metal and sparks Frequently inspect input power cable for wear and tear replace the cable immediately if damaged bare wiring is dangerous and can kill Do not use damaged undersized or badly joined ca...

Страница 4: ...essure If damaged a cylinder can explode Because gas cylinders usually are part of the welding cutting process be sure to treat them carefully CYLINDERS can explode if damaged Protect gas cylinders fr...

Страница 5: ...built in fan working to bring down the temperature inside the equipment The machine will be ready for use again when the internal temperature reaches a safe level Over Voltage Supply Regarding the pow...

Страница 6: ...6 RAZOR CUT 45 AIR COMPRESSOR OPERATING MANUAL 2 Package Contents Air Hose RAZOR CUT 45 Air Compressor Mounting Brackets Screws...

Страница 7: ...ns Technical Data Parameter Values SKU U14007 Input Amperage 3 7 5 Rated Power 780 Watts 5 Rated Air Pressure MPa 0 25 0 05 Maximum Instantaneous Working Pressure MPa 0 4 Dimensions mm 463 187 236 Wei...

Страница 8: ...IR COMPRESSOR OPERATING MANUAL 4 Compressor Layout 4 1 Front Panel Layout 1 Intlet Air Filter Covers 4 2 Rear Panel Layout 2 Air Outlet 3 Compressor Operation Indicator 4 Power Input Cable for RAZOR C...

Страница 9: ...side of the bracket is meant for the CUT 45 and the longer side is for the compressor 2 After installing both brackets on the base of the CUT 45 carefully lower the machine onto the compressor Ensure...

Страница 10: ...CUT 45 6 You are now ready to plug your RAZOR CUT 45 in and use it The compressor will automatically kick on when more air flow is needed The RAZOR CUT 45 Air Compressor has two air filters located a...

Страница 11: ...er The UNIMIG Plasma Cutter Air Filter eliminates contaminants such as sputter caused by moisture and oil from compressed air lines With new and improved technology the plasma air filter is able to en...

Страница 12: ...FICE 19 Commerce Cct Yatala QLD 4207 PH 07 3333 2855 FAX 07 3274 5829 EMAIL qld unimig com au VIC OFFICE 91 Yellowbox Drive Craigieburn VIC 3064 PH 03 8682 9911 FAX 03 9333 7867 EMAIL sales unimig com...

Отзывы: