Unimark EC3000 Series Скачать руководство пользователя страница 23

 

Page 23 of 24  

71U-1409-300K; REV 20 

EC3000 Installation and Operator’s Manual 

TO

 - 

Time Out setting command is used to set the period of time the Unit will wait for the host to respond to a coupon 
process  (coupon  read  and  data  sent  to  host system) before the process is terminated and the Unit is released to 
process another coupon.  Unit will send an ERR1 response to the host when the timeout occurs. 

HOST command sequence:  

[STX]TO[ETX] 

Unit response: 

[STX]“HCTC”TOOKnn[ETX] ; Report the current timeout setting 

HOST command sequence:  

[STX]TOnn[ETX] 

Unit response: 

[STX]“HCTC”TOOKnn[ETX] 

HOST command sequence:  

[STX]TO#nn[ETX] 

Unit response: 

[STX]“HCTC”TOOK#nn[ETX] 

Where:  

nn

  is  the  time  out  period  in  seconds  (01  –  99;  00  =  infinite  or  no 

timeout) 

US

 - 

Universal  Status  command  generates  a  status  response  with  PECTAB,  Program  Version,  and  Hard  Coded 
Transaction Code status information. 

HOST command sequence:  

[STX]US[ETX] 

Unit response: 

[STX]“HCTC”USOKPSOKVxVxVxyzVxyzPVOKvvvvvvvvvvCTOK“HCTC”[ETX] 
Where:  

VxVxVxyzVxyz

 are the loaded PECTABs 

vvvvvvvvvv

 is the 10 digit version number being reported 

“HCTC”

 is the 1 – 5 character Hard Coded Transaction Code 

Notes:  1.  [STX] represents the Start of Text character (02

HEX

).  Do not send the actual [STX] string. 

2.  [ETX] represents the End of Text character (03

HEX

).  Do not send the actual [ETX] string. 

3.  Refer to the AEA standard for further details on these commands. 
4.  EC3:   is the default Hard Coded Transaction Code “HCTC” for the Unit in Generic AEA mode.  This may 

vary for other operating modes such as CUTE which is 5 spaces by default. 

 
 
 
 
12.2  AEA Error Messages 

ERR1

 - 

Indicates  that  the  operator  has  manually  reset  the  coupon  processing  sequence  by  pressing  the  RESET 
button, or an internal timeout has been reached and the Unit resets the processing sequence. 

ERR2

 - 

Illogical  Command  Received.    Sent  to  the  host  system  if  any  command  outside  the  AEA  or  Non -AEA 
commands listed here is used. 

ERR5

 - 

Unsuccessful Magnetic Processing Operation.  Used specifically to notify the host when the Unit detects an 
ATB  Magnetic  coupon  processing  attempt  but  no  magnetic  data  is  read.    Possible  circumstances  for  this 
error  would  include  swiping  a  coupon  upside  down,  coupon  is  not  encoded,  or  a  non-magnetic  coupon/E-
ticket is used. 

ERR6

 - 

No parametric table (PECTAB) available for the magnetic coupon swiped. 

ERR7

 - 

The  Unit  responds  with  this  error  when  receiving  a  non-CB/CC/CE  AEA  command  after  starting  the 
processing of an ATB magnetic or Bar Code coupon. 

ERR8

xx

 -  Erroneous element detected in PECTAB download.  

xx 

defines the first detected erroneous element. 

ERR9

 - 

PECTAB exceeds memory capacity of Unit. 

ERRP

 - 

When  the  Unit  receives  the  KP  command,  it  switches  to  a  special  firmware  download  mode.    This  error 
message is sent to the host as a response to any AEA command received except the PD (program download) 
command and certain others sometimes allowed in this state such as program version (PV). 

Содержание EC3000 Series

Страница 1: ...www unimark com Unimark Service USA 800 255 6356 or 740 201 0080 EC3000 Series P N 71U 1409 300K 2008 REV 20 Installation Operator s Manual...

Страница 2: ...e 19 11 0 Customer Technical Support Page 20 11 1 Return Authorization Customer Service 11 2 Technical Support 12 0 Commands and Responses Page 21 12 1 AEA Commands Sequences 12 2 AEA Error Messages 1...

Страница 3: ...le mounting platform to secure the Unit to any counter surface The magnetic stripe reader option will accept full size ATB coupons the ATB flight coupon section the ATB boarding pass stub and Wallet t...

Страница 4: ...attachments The Unit must be installed on a flat and stable surface Do not install the Unit where it will be exposed to direct sunlight Sunlight will affect the bar code scanner s ability to read boa...

Страница 5: ...ward from the Mount 3 Verify the Unit is clear of the Mount 4 Remove the cables from the rear of the unit Installing the Unit onto the Mount 1 Make sure all required cables are connected 2 Align the U...

Страница 6: ...l power supply module The external power supply module incorporates an IEC 320 power connection accepting 110 220VAC 50 60Hz The power supply module must be plugged into a properly grounded outlet to...

Страница 7: ...Page 7 of 24 71U 1409 300K REV 20 EC3000 Installation and Operator s Manual Counter Top Version Connector Access...

Страница 8: ...m the Unit depends on FW option CR Carriage Return character 0DHEX Used in conjunction with LF to separate magnetic TRACK and BLOCK fields DC1 XON character 11HEX Used to indicate that the host serial...

Страница 9: ...s accurately scanned and transmitted The AEA CB CC and CE or equivalent non AEA protocol commands are used to generate audible and visible indications of Ok to Board or Do Not Board conditions same as...

Страница 10: ...BC data only with carriage return after the data STX AIM ID Bar Code Data ETX Standard BC data with AIM ID STX SITA ID Bar Code Data ETX Standard BC data with SITA C Mode ID STX AEA ID Bar Code Data E...

Страница 11: ...e t bracket so that the interface cable connection located at the rear of the unit 7 1 3 Remove the screws from the bottom of the swipe reader and secure the t bracket to the reader 7 1 4 Remove the t...

Страница 12: ...eader as long as the magnetic strip always faces directly towards the face of the magnetic head The coupon symbol on top of the reader indicates proper coupon orientation The Unit reads and transmits...

Страница 13: ...sert any other kind of printout except ATB coupons 4 Avoid inserting coupons which have staples in them If this is unavoidable make sure staples are placed in the center of the coupon Staples placed a...

Страница 14: ...TAB elements per the AEA standard This mode can drastically reduce the amount of data sent to the host system and uses the processing power of the Unit to sort through the magnetic data instead of the...

Страница 15: ...Reset Button A Reset button is provided to allow the operator to perform a hard reset or restart of the Unit same as a full power cycle The button s function is indicated by the symbol During any poin...

Страница 16: ...sity levels of the audible indicator Stop at the desired level and then power cycle the Unit This will save the setting and re initialize the unit 8 5 Power ON Indicator A single light source is provi...

Страница 17: ...id looking into the scanner light source 2 Locate a soft non abrasive lint free cloth 3 Wipe the lens area see diagram below for lens location 4 If some particles continue to cling to lens area use ca...

Страница 18: ...ader the only acceptable cleaning solution is 99 Isopropyl Alcohol NEVER use a water based solution to clean rollers or read head Some water based solutions can damage the rubber elastomer on the roll...

Страница 19: ...t Relocate the Unit if necessary 10 4 2 Shade the display with your hand If the display still cannot be seen return the Unit to Unimark or a certified service center 10 5 Bar code scanner will not tra...

Страница 20: ...IP WITH RECEIPT PAPER ROLL INSTALLED 11 1 2 Packaging Use original packaging materials or equivalent If not available Unimark can provide at a small cost 11 1 3 Enter the RA on the packing list and on...

Страница 21: ...ator time period Unit response STX PTTC PROK ETX after magnetic coupon has been read STX HCTC PROK ETX after bar code coupon has been read There are variations of this command intended to control cutt...

Страница 22: ...ming the host system supports the download function HOST command sequence STX PDvvvvvvvvvvbbbbbbb ETX Unit response STX HCTC PDOKvvvvvvvvvv ETX Where vvvvvvvvvv is the 10 digit version number being lo...

Страница 23: ...etails on these commands 4 EC3 is the default Hard Coded Transaction Code HCTC for the Unit in Generic AEA mode This may vary for other operating modes such as CUTE which is 5 spaces by default 12 2 A...

Страница 24: ...rred in shipping Any warranty work to be performed by Unimark shall be subject to Unimark s confirmation that such product meets Unimark warranty In the event of a defect covered by its warranty Unima...

Отзывы: