Chapter 6 Troubleshooting and Component Replacement
64
6.1.6 Failure in Lighting up Part of the Modules in the Cabinet
Causes:
1) Output of the power supply for the modules is faulty.
2) Output of signal which controls the related modules is faulty.
Troubleshooting method:
1) Check DC voltage for the modules.
2) Check the hub card ports or flat cables that control the modules.
6.2 Replacement of Main Components
Before performing maintenance on the LED display, cut off the power supply to ensure
your personal safety and equipment safety.
6.2.1 Replacement of Module
Cut off the power supply of the display , replace a module of the LED display based
on the following steps:
Front maintenance step
Picture
Description
Step 1
Find the faulty cabinet and
disconnect the power supply
Step 2
Use vacuum suction tool to
suck out the failure module
and replace it