Configure
Enable/Disable Calibration
to
Brightness
, click
Save
, and then click
Manage Coefficients
to display the following window:
Fig 3-14 Manage Coefficients
Upload coefficients:
Upload the correction coefficient database generated by
the software or read back by the display screen to the screen.
Save coefficients to database:
Read back and save the coefficients from the
screen to the coefficient database.
Set coefficients for a new scan board:
After replacing the scan board (receiving
card), set the correction coefficients for the new receiving card.
Set coefficients for a new module:
After replacing a module, set the correction
coefficients for the new module.
Adjust Coefficients (Color is uniform on screen):
Adjust the correction
coefficients for a selected area on the screen to achieve a satisfactory effect.
Erase or reload Coefficients:
Erase or reload the correction coefficients for a
selected area on the LED display.
Reset Correction Coefficients:
Reset the calibration coefficients on whole or
selected section of LED display.