OPERATION

Battery Display

Run Time Count Down

Setting

Button

Run Time Setting Decrease

Main Lamp Button

Trigger

Switch

Run Time 

Setting 

Increase

Ultrasonic Range Finder Distance 

General Operation 

- Put the UV protection glasses            on and do not 
remove them while the UV light is being emitted.
- Press the              button for more than 1 second to 
Power on or off. Then pull the trigger          to switch 
the UV light on or off. 

Locking Protection System

- Double click                 to lock or unlock the lamp when 
the power and display screen is off. 

Setting Procedure

- Press         button once to start the ‘minutes’ setting 
mode, the minutes display will keep flashing. 
Press          or         button to adjust the minutes 
required (max 10).
-  Press                button  again  to  enter  the  ‘seconds’ 
setting mode, seconds display keep flashing.    

Press            or             button to adjust the seconds 
required (max 60).
- Press and hold             or            buttons to adjust faster. 
The maximum time can be set to "10:00" minutes.  
- Press          button for 5 seconds to confirm the setting 
chosen.
- The countdown will start after the trigger         has been 
pressed. 
- The countdown can be paused when the trigger        
is pressed once. It will continue after the trigger         is 
pressed again.
- When the lamp is switched off                the next time 
it is switched back on               it will remember the last 
countdown setting used. 
- The UV light will automatically switch off when the 
remaining time on the display shows "                ".
-  The  lamp  will  automatically  power  off  after  60 
minutes of no operation.

UV-CURE

 

CURING LAMP 

/ 395nm

Содержание UV-CURE

Страница 1: ...WARNING Read this manual before using this product Failure to do so can result in serious injury KEEP THIS MANUAL FOR REFERENCE UV CURE PROFESSIONAL RECHARGEABLE CURING LAMP...

Страница 2: ...le switched on risk of fire WARNING Up to 1s curing time for some UV primers Powerful irradiance with maximum UV A intensity of 55 000 W cm at 20 cm 8 inches Successfully tested on UV paint products b...

Страница 3: ...2 3 4 5 6 TECHNICAL SPECIFICATIONS Ultrasonic Range Finder Temperature Control Function Safety Protection Function Curing Distance Curing Area Curing Time Average Irradiance Peak Irradiance Max 400cm...

Страница 4: ...keep flashing Press or button to adjust the minutes required max 10 Press button again to enter the seconds setting mode seconds display keep flashing Press or button to adjust the seconds required ma...

Страница 5: ...75 C 167 F and below 90 C 194 F a warning buzzer will activate and gives an alarm every 30 seconds during the regular working period The buzzer will stop when the end of the countdown shows or the lam...

Страница 6: ...onto the 15V 1 5A universal charger Switch the light off and put it in the wall mounted charging station Connect the charging station with the 15V 1 5A universal charger The charging port on the handl...

Страница 7: ...the event of any doubt Dispose of any packaging materials via an environmentally friendly disposal facility WARRANTY The device has a 1 year WARRANTY against manufacturing faults or defects The guara...

Отзывы: