Unika PS-5000 Скачать руководство пользователя страница 14

Manual

PS Series Amplifier

PS-5000 PS-4000 PS-3000

Professional Amplifiers
for Live Sound

w w w . u n i k a . c o m .  t w

UNiKA

13

TECHNICAL DATA

SPECIFICATIONS

 

PS-3000

 

PS-4000

 

PS-5000

 

Both Channel Driven 

8 Ohm

 

600 W

 

900 W

 

1200 W

 

Both Channel Driven 

4 Ohm

 

980 W

 

1400 W

 

1900 W

 

Both Channel Driven 

2 Ohm

 

1350 W

 

2000 W

 

2500 W

 

Mono Bridge 8 Ohm

 

1960 W

 

2800 W

 

3800 W

 

Mono Bridge 4 Ohm

 

2700 W

 

4000 W

 

5000 W

 

Circuitry

 

bipolar, class-H

 

Frequency Response

 

20 Hz - 20 kHz +/- 0.5 dB,    1 dB below maximum 
performance

 

Total Harmonic 

Distortion

 

less than 0.01% @ 1 kHz

 

Input Impedance

 

20 k Ohm balanced

 

Operation Mode

 

Parallel-Mono, Stereo and    Bridge

 

Voltage Gain

 

switchable    26 dB , 32 dB or 1.4V

 

Limiter

 

switchable    Peak - Limiter

 

Ground-Lift

 

ground - lift switch on back panel

 

Cooling

 

2 Speed Fan , Front - to - Rear Forced Air

 

Indicators

 

LED's for ON, SIGNAL, CLIP, at Both Channel . Parallel, 
Stereo and Bridge, for Function Mode

 

Input Connectors

 

XLR Male / Female

 

Output Connectors

 

one 4-pole SPEAKON connector for each output channel 
(channel 1 & channel 2),

 

one 4-pole SPEAKON connector exclusively for Mono 
mode

 

Protection Circuits

 

Turn - on Delay, Short Circuit, DC, Current Limiter, Over 
temperature Protection,

 

Signal to Noise Ratio

 

< -105 dB

 

Damping Factor

 

> 800 : 1

 

Dimensions (WxHxD)

 

483 x 133 x 464 mm

19", 3U

 

Shipping 

Dimensions(WxHxD)

 

615 x 215 x 580 mm

 

Net Weight

 

32.5 kg

 

35.5 kg

 

37 kg

 

Shipping Weight

 

36.5 kg

 

39.5 kg

 

41 kg

 

Содержание PS-5000

Страница 1: ...Manual w w w u n i k a c o m PS Series Amplifier PS 5000 PS 4000 PS 3000 Professional Amplifiers for Live Sound UNiKA...

Страница 2: ...o drive professional loudspeakers without clipping Oversized toroidal transformer filter and heat sinks for better low end transparency and stability Comprehensive protection circuitry short overheat...

Страница 3: ...tation company immediately Only you can initiate a claim for shipping damage UNiKA will be happy to help as needed Save the shipping carton as evidence of damage for the shipper s inspection We also r...

Страница 4: ...a standard 19 inch 48 3 cm equipment rack You may also stack amps without using a cabinet NOTE When transporting amplifiers should be supported at both front and back Ensure Proper Cooling When using...

Страница 5: ...damage to you equipment Be sure that AC power is OFF and all level controls are set to MINIMUM before mak ing connections This will eliminate any chance of unexpected loud audio transients that could...

Страница 6: ...egative Operation Mode Switch 2 Switch is used to set the unit for Parallel mode Stereo mode and Mono Bridge mode Gain switch 3 Ps series amplifiers let you select different input sensitivities respec...

Страница 7: ...source disconnects from the amplifier s ground preventing ground loops which can generate hum and noise See the Signal Ground Lift Switch instructions for more detail Speaker Outputs 6 Connectors are...

Страница 8: ...check that power is being supplied from the mains outlet If so but the LED s still have not lit up Parallel LED 9 The parallel LED will light when you have set the rear panel MODE SWITCH 2 for parall...

Страница 9: ...better control of the remaining headroom of a channel or a complete system Clip LED 13 The clip LED indicates the exact clipping point regardless of the mains voltage and or the connected load The sy...

Страница 10: ...l The other channel 1 channel 2 input can be used to link to an additional amplifier 3 Connect the loudspeakers to the channel 1 and channel 2 SPEAKERS OUTPUT 6 THE TOTAL SPEAKER LOAD MUST BE AT LEAST...

Страница 11: ...her channel 1 input can be used to link to an additional amplifier 3 Connect the loudspeakers to the channel 1 and channel 2 SPEAKER OUTPUT 6 THE TOTAL SPEAKER LOAD MUST BE AT LEST 2 OHM PER CHANNEL I...

Страница 12: ...nel will light LED does not illuminate you have the switch in the wrong position Correct it before continuing 2 With the power off connect your input cables to channel 1 input only using the either th...

Страница 13: ...D LIFT SWITCH Depending on you system configuration sometimes applying the ground will create a quieter signal path Sometimes lifting the ground can eliminate ground loops and hum to create a quiter s...

Страница 14: ...Mode Parallel Mono Stereo and Bridge Voltage Gain switchable 26 dB 32 dB or 1 4V Limiter switchable Peak Limiter Ground Lift ground lift switch on back panel Cooling 2 Speed Fan Front to Rear Forced A...

Страница 15: ...Manual PS Series Amplifier PS 5000 PS 4000 PS 3000 Professional Amplifiers for Live Sound w w w u n i k a c o m t w UNiKA 14...

Страница 16: ...WWW http www unika com tw E Mail unika unika com tw Tel 886 2 2793 3017 Fax 886 2 2792 8264 6F No 168 Xinhu 2nd Rd Neihu Dist Taipei City 114 Taiwan R O C...

Отзывы: