Unigreen Minibar Скачать руководство пользователя страница 12

12

  unigreen

4.8

PRESSURE REGULATOR

To use the pressure regulator, follow the instructions in the enclosed hand-
book scrupulously. The pressure regulator controls all of the most important
spraying functions, the thorough knowledge of its functions makes work easier
and more precise.
The working pressure and the maximum pressure of the sprayer are deter-
mined by the pressure regulator which also protects the circuit from
overpressure in any work conditions. (In serious but very rare cases, if the
connecting pipes get blocked the pressure relief valve lets the pressure off)
In some setups there may be a pump that can reach a pressure of 50 bar
controlled by a regulator designed for 20 bar. In this case the maximum
pressure that can be reached is 20 bar.
The regulators can be manual, mounted on the sprayer or at a distance to
make the controls easier to use; or electrical with a control panel in the cabin.
There are also regulator versions with mechanical remote controls with a
cable. If the tractor has a waterproof cabin the use of electrical controls is
obligatory.

4.8.1 COMPONENTS OF THE PRESSURE REGULATOR

Below you will find the indications for the main models fitted on Unigreen
products.

A main ON-OFF command

: “open” lets the fluid flow into the circuit in use;

“closed” empties the tank.

B maximum pressure valve

: adjusted by hand with the relevant knob (drains

the excess liquid when the set pressure is reached).

C jets section tap

: opens the corresponding jet boom or drains to the

compensation regulator (G).

D auxiliary tap

: can be used for various accessories (it is always manual).

E volumetric pressure valve (proportional)

:

(when present) it regulates the spraying pressure. The valve automatically
compensates variations in speed (within the scope of the same gear ratio),
keeping the quantity of liquid supplied per surface unit (litres/hectare)
unchanged.

F self-cleaning filter

: filters the delivery liquid.

G compensation regulators

: suitably regulated, these make it possible to

keep the pressure constant when one or more sections of jets is closed, they
don’t influence treatments with the boom fully open.

H manometer

: indicates the working pressure.

Connections:

R1 

supply union

R2 

drain union

R3 

volumetric drain union

R4 

jets section delivery union

R5 

auxiliary delivery union

Control box for GCP ELETTRICO electrical regulators
I1 

main control valve switch

I2 

volumetric pressure valve switch (proportional)

I3 

jets section valves switches

4.8.2 GENERAL INSTRUCTIONS

When using the pressure regulator, scrupulously observe the instructions in
the enclosed handbook, below you will find generic indications for the major
models fitted by Unigreen.

All the regulation and adjustment tests must be carried out with clean
water.

Pressure regulators without a volumetric valve 

(GCP3-way - GRH-RVA)

Adjusting the maximum pressure valve
=

put main control 

A

 in the drain position (“OFF”).

=

loosen the hand wheel of maximum pressure valve 

B

 completely

(anticlockwise).
=

start the pump by activating the power-takeoff of the tractor at 540rpm

=

open main control 

(position “ON”), the manometer will be activated

=

open all of the section valves 

C

 (position “ON”)

Don’t use the sprayer
without having consulted
the enclosed handbook.

Содержание Minibar

Страница 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS AIRDROP MFC MOUNTED MISTBLOWERS serie AIRDROP P ELETTRA P MFC P Ventagli Minibar Super Spalliera RV GDC Read this manual carefully before use GB...

Страница 2: ...ACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4 8 1 COMPONENTS OF TH...

Страница 3: ...8 7 1 MATERIALS FOR DEMOLITION 24 8 7 2 INDICATIONS FOR A SUITABLE TREATMENT OF WASTE 24 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 24 TABLES FOR CALIBRATING AIRDROP 2 VENTAGLI FANS VR CANOP...

Страница 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Страница 5: ...h the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms 20 19 22 21 2 1 6 3 4 5...

Страница 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Страница 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Страница 8: ...omponents for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTRUC...

Страница 9: ...fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting g...

Страница 10: ...Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie...

Страница 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Страница 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Страница 13: ...t the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat the...

Страница 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Страница 15: ...llow for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the suppl...

Страница 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Страница 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Страница 18: ...er versions moving the left hand distributor to the right hand and vice a versa the same inversion must be performed for the two distributor taps 1 2 3 4 For particularly high espaliers an upper doubl...

Страница 19: ...components and in particular to the pipes to prevent the risk of bursting Do a full check on the pipes and components at least once a year we recommend replacing hydraulic pipes every 3 4 years 5 4 1...

Страница 20: ...means a big advantage in terms of uniformity and homogeneity of the jet 6 3 MIXTURE CONCENTRATION As you may know the pneumatic equipment are used for more or less concentrated treatments To prepare t...

Страница 21: ...ce 3 5 m volume in l ha 600 x 5 6 177 8 l ha 3 5 x 5 4 6 4 1 BATCHING TAPS SEE PICTURE 20 On the equipment VENTAGLI FANS there are two batching taps which can be used to quickly change the flow rate t...

Страница 22: ...e is controlled by opening lever A which depending on how much it s pressed produces a conical spray or direct jet The standard nozzle is 1 5 The mitra spray gun can produce a direct jet or a conical...

Страница 23: ...lly in the first period of use We recommend replacing the oil after the first 50 working hours and then subsequently every 500 hours The quantity of oil needed is indicated on the sticker near the mul...

Страница 24: ...TABLE TREATMENT OF WASTE The Correct management of special waste envisages stocking in suitable places avoiding mixing dangerous waste with the non dangerous ensuring that authorised carriers and rece...

Страница 25: ...137 154 173 192 233 263 281 324 365 370 425 477 472 535 8 112 120 135 152 168 204 230 246 283 319 324 372 418 413 468 2 5 m 4 187 200 225 253 280 340 384 410 472 532 540 620 696 688 780 5 150 160 180...

Страница 26: ...5 150 160 189 216 253 280 302 346 384 6 80 91 96 125 133 157 180 211 233 252 288 320 3 7 69 78 82 107 114 135 154 181 200 216 247 274 8 60 68 72 94 100 118 135 158 175 189 216 240 3 m Litri min 2 40 2...

Страница 27: ...TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 0578F Velocit Km h speed Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Страница 28: ...17 3 19 2 20 1 21 5 TOTALE total Litri min 0 67 0 76 0 88 0 96 1 11 1 22 1 3 1 39 1 31 1 45 1 57 1 68 2 17 2 41 2 52 2 69 SINGOLA single Tab 3215 000F Litri ha Litri ha Litri ha Velocit Km h speed Ve...

Страница 29: ...1 5 nozzle DIAMETER NOZZLE 1 0 1 2 1 5 1 75 2 0 2 2 2 5 PRESSURE BAR JET CAPACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2...

Страница 30: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Страница 31: ...1 X X X X APS 96 PRESSURE GCP 2 ELECTRIC X X X X REGULATOR GCP 2 ELECTRIC PRES X X X X NOZZLES MFC X X X X DISTRIBUTOR 2 VENTAGLI X X X X ACCESSORIES MINIBAR X X X X SUPER SPALLIERA X X X X RV X X X R...

Страница 32: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Отзывы: