LMV5x program operating phases
Phase number
Description
Sequence
10
Home
run
12
Stand
by
20,21
Waiting to start realase
Startup
22
Start fan on
Startup
24 Driving
to
pre-purge Startup
30....34 Pre
purging
Startup
36
Driving to ignition pos
Startup
38 Ingnition
pos
Startup
40,42,44
Fuel release 1
Startup
50,52
Fuel release 2
Startup
54
Driving to low flame
Startup
60,62 Shut-down
low
fire
Operation
70,72 Driving
to
prepurge
Shutdown
74....78 Post-prepurging
Shutdown
79
Test Air PressSwitch
Shutdown
80....83
Valve
proving
01
Safety
Phase
00
Lockout
At burner startup, the AZL display shows, one by one, the various phases of the start-up program, until it reaches normal operation phase (Phase 60).
LMV5x controller is factory preset. Changing are possible according to the password input
By closing the "thermostat series" and once the start-up sequence is accomplished (from phase 12 to pahse34), the burner is driven to the factory-set
ignition position (phase 38).
The burner remains in that position because this is the only one work point in memory.
The fuel/air ratio curve must be set, until the maximum load limit (100% output).
During the setting, the actuators move according to the curve points. While the actuators move, always check the combustion analysis, point by point,
and the flame stability.
The fuel/air curve points must be set during the commissioning, by a qualified operator.
CAUTION! The procedure requires a password: qualified personnel only must check all changes to combustion parameters by
means of the combustion analyzer. Remember that the password will elapse if no key is pressed for a certain period. The unit will
ask for the password again
ATTENTION! During the cold start phase, it is necessary to set the burner load. Too low output values could damage the
combustion head, blast tube, oil nozzle (if present). The minimum working point must be set by qualified personal.
CAUTION!
:
check the combustion analysis, point by point, and the flame stability.
ATTENTION! Set the real load output percentage at the corresponding curve-point on AZL during the burner regulation.
Содержание RG2050
Страница 26: ...PART III OPERATION 26 Pump flow rate Nozzle flow rate...
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 37: ...Siemens LMV5x Service Manual M12920CC rev 2 1 08 2017...
Страница 44: ...8...
Страница 45: ...9 1 4 1 Servomotor wiring example 1 4 2 Bus cable wiring on LMV5x and AZL doors 1 4 3 EARTH connection example...
Страница 48: ...12 2 2 LMV5x program structure...
Страница 75: ...39...
Страница 82: ......
Страница 83: ......
Страница 84: ...Note Specifications and data subject to change Errors and omissions excepted...
Страница 86: ...Annex1 Example for motor cable...
Страница 87: ......
Страница 88: ...Annex 2 Example for sensor cable...
Страница 89: ......
Страница 90: ......
Страница 94: ......