![Unigas PN30 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/unigas/pn30/pn30_operating-and-maintenance-instructions_842314012.webp)
PART I: INSTALLATION MANUAL
12
SELECTING THE OIL NOZZLES
Tab. 1 - Nozzle flow rate in relation to oil pressure
OIL PUMPS
Key
1 Pressure adjustment
2 Pump pressure gauge
3 Vacuum gauge
5 Nozzle
7 Suction
8 Return
Note: the 1069 pumps are fitted with mechanical seal and electric pre-heater (80 W).
NOZZLE
G.P.H.
PUMP PRESSURE bar
24
25*
26
1,35
8,70
8,90
9,10
1,50
9,70
9,90
10,10
1,65
10,60
10,90
11,10
1,75
11,30
11,50
11,70
2,00
12,90
13,20
13,40
2,25
14,50
14,80
15,10
2,50
16,10
16,50
16,80
3,00
19,30
19,70
20,10
3,50
22,50
23,00
23,50
4,00
25,80
26,30
26,80
4.50
29.00
29.60
30.20
5.00
32.20
32.90
33.60
* Pressure set in the factory
Pump Suntec E4
Suction height
0.5 bar
Advised value to prevent air separation from oil
0.35 bar
Rated speed max.
max. 3600 g/m
Operation viscosity
from 2.8 to 800 cSt
Oil temperature
Type 1001: max, 90° C
Type 1069: max. 120° C
Maximum pressure in the suction and return
piping
Type 1001: 1.5 bar
Type 1069: 3.5 bar
Type 1001 and 1069: 3.5 bar
SUNTEC PUMPS
N-.AB...
E-.AB...
D-.AB...
PN30
E4 NC 1001
E4 NC 1069
E4 NC 1069