PART I: INSTALLATION

26

.

5

go on adjusting air and gas flow rates: check, continuosly, the flue gas analisys, as to avoid combustion with little air; dose the air
according to the gas flow rate change following the steps quoted below; 

6

drive the burner to high flame stage, by means of the thermostat 

TAB (except single-stage models)

.

7

acting on the pressure stabiliser of the valves group, adjust the 

gas flow rate in the 

high flame stage

 as to meet the values requested by the boiler/utilisation: 

Multibloc MB-DLE:

The pressure governor is adjusted by operating the screw 

VS

located under the cover 

C

. By screwing down the pressure is increased and by

unscrewing it is reduced.

 

The valve is adjusted by means of the 

RP

 regulator after sla-

ckening the locking screw 

VB

 by a number of turns. By unscrewing the regulator 

RP

the valve opens, screwing the valve closes. The pressure stabilizer is adjusted by
operating the screw 

VS

 located under the cover 

C

. By screwing down the pressure is

increased and by unscrewing it is reduced.

Pressure stabiliser is factory-set. The setting values must be locally adapted 

to machine conditions. Important! Follow the instructions of the burner manufactu-
rer!

To adjust the air flow rate

, proceed as follows, according to the burner operation (single-

stage, double-stage, prograssive or fully-modulating).

Adjustements for single-stage burners

8

loosen 

VR

 screw (see picture below)

9

move the 

ID

 index t or -, in order to increase or decrease the air flow-rate, according to the required combustion values;

10 fasten the 

VR

 screw again.

Double-stage, progressive or fully-modulating burners

11 still in the high flame operation and with the actuator on its 90° position, find the 

screw on the adjusting cam 

SV

 (see next pic-

ture), matching with the bearings that move along the foil and related to the actuator position.

12 unscrew the 

V

 srew to increase the air folw rate, unscrew to decrease it

13 once the maximum flow rate is fixed, shortcircuit for a while, the thermostat 

TAB

 T6 and T7 terminals (see pag. 35), as far as the

fully-modulating burners, see next paragraph. The actuator will move towards the low flame position as to meet the next screw 

V

;

then remove the bridge;

14 then adjust the screw 

V

 related to that position;

15 shortcircuit, again for a while, the 

TAB

 T6 and T7 terminals and repeat from point 11;

16 repeat all these instructions for all the actuator stroke, in order to define the foil shape.

Note:

 If it should be necessary to adjust the rating of the burner in low flame, work on the related actuator cam After this operation,

check the gas rate and verify the combustion values. In case of lack or excess of air,  work on the screws 

V

 of the adjusting cam (see

pictures) matching the setting point of the air rate in low flame; unscrew to increase the air rate or screw to decrease it.

Fully modulating burners

To adjust the air rate in low flame and in the intermediate points, proceed as follow.
1

Keep pushed for 5 seconds the EXIT button on the modulator (); when the LED with the hand symbol lights up, press the arrow but-
ton, driving the actuator to the maximum opening position progressively;

2

stop its stroke when it meets each screw 

V

: adjust the air rate by adjusting the 

V

 screw that matches each bearing.

3

Push the EXIT button to quit the manual mode.

Adjusting the combustion head

The burner is factory-set with the combustion head at the position that refers to the "MAX" output. The maximum output setting refers to
the  “fully-ahead” position of the combustion head, as far as standard models (Fig. 34), and to “fully-backward” position for low NOx bur-
ners (Fig. 35). As for “fully-ahead” position, it means that the head is towards the boiler,  “fully-backward” position means that the head

Fig. 31

Fig. 32

C

VS T(VR)

RP

VB

VSB

VR

ID

V

SC

SV

Содержание IDEA LG550

Страница 1: ...IDEA Series Gas burners MANUAL OF INSTALLATION USE MAINTENANCE BURNERS BRUCIATORI BRULERS BRENNER QUEMADORES M039119CE Rev 5 3 11 2021 LG550 NG550 NGX550 LGX550...

Страница 2: ...e employed exclusively for the use for which it was designed Before connecting the burner make sure that the unit rating is the same as delivery mains electricity gas oil or other fuel Observe caution...

Страница 3: ...ixtures DIRECTIVES AND STANDARDS Gas burners European directives Regulation 2016 426 UE appliances burning gaseous fuels 2014 35 UE Low Tension Directive 2014 30 UE Electromagnetic compatibility Direc...

Страница 4: ...quipment of machi nes EN 60335 2 Electrical equipment of non electric appliances for house hold and similar purposes Safety requirements Burner data plate For the following information please refer to...

Страница 5: ...dulating burners the electric actuator 7 that moves proportionally the air damper and the gas butterfly valve uses an adjusting cam with variable shape This one allows the optimisation of the gas flue...

Страница 6: ...ers with flame reversal in this case the blast tube must penetrate at least 50 100 mm into combustion chamber in respect to the tube bundle plate The length of the blast tubes does not always allow th...

Страница 7: ...vice Internittent BURNERS NG550 M xx 0 25 NG550 M xx 0 32 NG550 M xx 0 40 NG550 M xx 0 50 LG550 L xx 0 25 LG550 L xx 0 32 LG550 L xx 0 40 LG550 L xx 0 50 Output min max kW 160 570 Fuel Natural gas L P...

Страница 8: ...alid for G20 gas net calorific value Hi 34 02 MJ Stm3 for L P G net calorific value Hi 93 5 MJ Stm3 Note2 Maximum gas pressure 360mbar with Dungs MBDLE MBC valves Minimum gas pressure see gas curves f...

Страница 9: ...s Draw a vertical line matching the furnace input value 600kW in the example quoted on the x axis as far as intercepitng the network pressure curve according to the installed gas train DN65 in the exa...

Страница 10: ...head is set in order to find a compromise between the burner output and the generator specifications that is why the minimum output may be different from the Performance curve minimum Pressure in the...

Страница 11: ...in the diagrams refer to GPL with a calorific value of 22300 kcal Stm3 15 C 1013 mbar and a density of 2 14 kg Stm3 When the calorific value and the density change the pressure values should be adjust...

Страница 12: ...jig and burner flange DN A S A L B S B L C D 5mm E 5mm F G H J K L M N Omin Oma x P Q R S T W X Y NG LG550 25 32 843 943 253 353 590 671 245 426 165 178 384 241 384 M10 247 157 192 174 552 377 175 69...

Страница 13: ...flange DN A S A L B S B L C D 5mm E 5mm F G H J K L M N Omin Oma x P Q R S T W X Y NGX550 LGX550 25 32 874 974 253 353 590 671 245 426 176 198 384 241 384 M10 247 157 192 174 552 377 175 69 543 533 16...

Страница 14: ...stion chamber as described on paragraph Overall dimensions 2 place the burner to the boiler lift it up and handle it according to the procedure described on paragraph Handling the burner 3 place the s...

Страница 15: ...item NOTE the bellow joint the manual valve and the gaskets are not part of the standard supply The procedures of installation fo the gas valves are showed in the next paragraph DANGER Incorrect moto...

Страница 16: ...fter mounting perform leakage and functional tests Once the train is installed connect the gas valves group plug Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 DANGER Incorrect motor rotation can se...

Страница 17: ...on reassembly modification repair 6 On completion of work perform a leak and functional test When wishing to monitor the test install a pressure gauge ranged to that of the pressure supply point PA F...

Страница 18: ...combustion head together 9 Fig 18 Rotate the disc D following the instructions below 10 Take off the screw VF Fig 18 11 Rotate the disc D for 180 and then fit the screw VF Fig 19 12 Reconnect CR and...

Страница 19: ...ion to the mains ATTENTION before executing the electrical connections pay attention to turn the plant s switch to OFF and be sure that the burner s main switch is in 0 position OFF too Read carefully...

Страница 20: ...FU3 LINE FUSE IL BURNER LINE SWITCH IM FAN MOTOR LINE SWITCH KM1 FAN MOTOR CONTACTOR LAF BURNER IN HIGH FLAME INDICATOR LIGHT LB INDICATOR LIGHT FOR BURNER LOCK OUT LBF BURNER IN LOW FLAME SIGNALLING...

Страница 21: ...FAN MOTOR FU3 LINE FUSE FU4 AUXILIARY FUSE IL BURNER LINE SWITCH IM FAN MOTOR LINE SWITCH KM1 FAN MOTOR REMOTE CONTACTOR SIEMENS RWF40 MODULATION REGULATOR LB BURNER LOCKOUT SIGNALLING LAMP LBF BURNE...

Страница 22: ...nical specifications Fig 29 Key 1 Pressure outlet on the combustion chamber 2 Gas pressure outlet on the butterfly valve 3 Differential pressure gauge 4 Fan air pressure plug Measuring the gas pressur...

Страница 23: ...ly until the normal combustion values are achieved WARNING NEVER LOOSE THE SEALED SCREWS OTHERWISE THE DEVICE WARRANTY WILL BE INVALIDATE The values in the diagrams refer to natural gas with a calorif...

Страница 24: ...PART I INSTALLATION 24 To perform the adjustments unscrew the fixing screws and remove the burner cover Keys 1 Valve group 2 Cover 3 Gas proving system 4 Control panel 5 Blast tube 3 4 1 5 2...

Страница 25: ...ge the burner setting during the testing in the plant follows the next procedure according to the burner operation Before starting the burner up adjust the valves group slow opening to set the slow op...

Страница 26: ...ove along the foil and related to the actuator position 12 unscrew the V srew to increase the air folw rate unscrew to decrease it 13 once the maximum flow rate is fixed shortcircuit for a while the t...

Страница 27: ...g ring nut VR until the burner locks read the pressure value on the scale of the pressure switch and set it again to a value reduced by the 15 Repeat the start up cycle and check the burner runs prope...

Страница 28: ...the transparent plastic cover on the pressure switch Adjusting the maximum gas pressure switch when provided To calibrate the maximum pressure switch proceed as follows according to its mounting posi...

Страница 29: ...E ANY OPERATION OF THE APPLIANCE MUST BE PREVENTED WHICH DEPARTS FROM THE INSTALLATION OPERATIONS OR WHICH HAPPENS AFTER TOTAL OR PARTIAL TAMPERING WITH THESE E G DISCONNECTION EVEN PARTIAL OF THE ELE...

Страница 30: ...signalling lamp or air damper opening during pre purge stage G Low flame operation signalling lamp H Ignition transformer in operation signalling light I EV2 opening signalling lamp L EV1 opening sign...

Страница 31: ...t the end of the pre purge phase the air damper goes to the ignition position the ignition transformer comes on signalled by the LED H and few seconds later the solenoid valves EV1 and EV2 are energiz...

Страница 32: ...er if the pressure difference between pressure connection 1 and 3 Fig 38 Fig 39 is twice as high compared to the last check You can change the filter without removing the fitting 1 Interrupt the gas s...

Страница 33: ...screw V1 is longer than the other and must be replaced in its seat 2 Slacken the butterfly valve adjusting rod Fig 45 and take it out pulling outside 3 Remove the connector CR of the ionization electr...

Страница 34: ...33 1 disconnect the cables from the electrodes ER detection electrode EA ignition electrode 2 loosen the fixing screw V 3 remove the electrodes and replace them observing the measures quoted on next...

Страница 35: ...less than the value shown check the position of the detection electrode the electrical contacts and if necessary replace the detection electrode see Electrodes position setting on page 35 Fig 51 Seas...

Страница 36: ...COVER FIXING SCREW 29 FRONT CONTROL PANEL 8 AIR INTAKE 30 FRONT CONTROL PANEL 9 AIR INTAKE 31 LIGHT 10 PRESSURE PLUG 32 LIGHT 11 BRACKET 33 CONTACTOR 12 COVER 34 LOCK OUT RESET BUTTON 13 FAIRLEAD 35 P...

Страница 37: ...PART III MAINTENANCE 37...

Страница 38: ...G MINIMUM GAS PRESSURE SWITCH PS LOCK OUT RESET BUTTON PT100 TEMPERATURE PROBE PT1000 TEMPERATURE PROBE RC RC CIRCUIT SATRONIC DLG976 CONTROL BOX SATRONIC DMG972 CONTROL BOX SD 0 10V VOLTAGE SIGNAL SD...

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ......

Страница 43: ......

Страница 44: ......

Страница 45: ......

Страница 46: ...ing time air pressure monitor LP and flame relay FR are tested for correct contact positions t11 Programmed opening time for actuator SA Only with LME22 The air damper opens until the nominal load pos...

Страница 47: ...d time for air pressure signal t11 Programmed opening time for actuator SA t12 Programmed closing time for actuator SA SB R W GP AL M LP BV1 Z FS tw t1 t3n TSA t4 7 t10 EK2 12 10 3 7 4 6 1 8 t3 A B B...

Страница 48: ...W Limit thermostat pressure switch Z Ignition transformer LME22 connection diagram NT PC control RESET EK FSV ION 1 2 3 M 4 BV1 5 7 Z 10 AL T 12 R W GP STB 9 7101 24 0606 pa 6 LP 8 EK 11 K1 K2 1 K3 K...

Страница 49: ...lt status is showed by the red LED inside the LME s lockout reset buttonaccording to the Error code table RESETTING THE BURNER CONTROL When lockout occurs the burner control can immediately be reset b...

Страница 50: ......

Страница 51: ......

Страница 52: ...ia L Galvani 9 35011 Campodarsego PD ITALY Tel 39 049 9200944 Fax 39 049 9200945 9201269 web site www cibunigas it e mail cibunigas cibunigas it Note specifications and data subject to change Errors a...

Страница 53: ......

Страница 54: ......

Страница 55: ......

Страница 56: ......

Страница 57: ......

Отзывы: