![Unigas G18 SP Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/unigas/g18-sp/g18-sp_manual_4050236009.webp)
PART I: INSTALLATION MANUAL
9
SETTINGS
G18 SP - PG25 SP
These burners are fitted with a double-regulation pump. The flame control device, a twin-stage one, after the pre-purgue stage,
energized the valve EV1 and the burner starts up.
After few seconds, the intervention of the second stage caused the energizing of the valve EV2, so the burner is feeded with a
maximum pressure of about 18 bar..
PG30 TN
Before carry out the settings, start-up the light oil pump proceeding as follows:
Before starting up the burner, be sure that the return pipe to the tank is not obstructed; any obstruction would cause the pump
seal to break.
start up the burner, light the photoresistor after the solenoid valve opening and leak the air from the manometer gauge.\
Light oil rate setting
The light oil rate is adjusted by chosing a nozzle with appropriate dimensions and setting the inlet pump pressure; to chose the
nozzle, refer to the tables below.
Light oil pump settings
G18 SP - PG25 SP
Adjust the pump for the ingnition, to a pressure value of about 8-10 bar. After 10”, the safety device drives the second stage; set
the pump to a pressure value of 18 bar, by means of the regulation screw.
PG30 TN
Set the pump to a pressure value from 10 to 14 bar, depending by the nozzle fitted (see Tab. 2).
Tab. 1 - Burners G18 SP - PG25 SP
Tab. 2 - Burner PG30 TN
Pressure (bar)
GPH
8
9
10
11
12
13
14
15
16
17
18
1.75
6.02
6.38
6.73
7.05
7.37
7.67
7.96
8.24
8.51
8.77
9.02
2.00
6.88
7.29
7.69
8.06
8.42
8.77
9.10
9.42
9.72
10.02
10.31
2.25
7.74
8.20
8.65
9.07
9.47
9.86
10.23
10.59
10.94
11.28
11.60
2.50
8.59
9.12
9.61
10.08
10.53
10.96
11.37
11.77
12.16
12.53
12.89
3.00
10.31
10.94
11.53
12.09
12.63
13.15
13.64
14.12
14.59
15.03
15.47
3.50
12.03
12.76
13.45
14.11
14.74
15.34
15.92
16.48
17.02
17.54
18.05
4.00
13.75
14.59
15.37
16.13
16.84
17.53
18.19
18.83
19.45
20.05
20.63
4.50
15.47
16.41
17.30
18.14
18.95
19.72
20.47
21.18
21.88
22.55
23.21
5.00
17.19
18.23
19.22
20.16
21.05
21.91
22.74
23.54
24.31
25.06
25.78
Pressure (bar)
GPH
10
12
14
3.50
13.45
14.74
15.92
4.00
15.37
16.84
18.19
4.50
17.30
18.95
20.47
5.00
19.22
21.05
22.74
5.50
21.14
23.16
25.01
6.00
23.06
25.26
27.29
6.50
24.98
27.37
29.56
7.00
26.91
29.47
31.84
Содержание G18 SP
Страница 18: ...PART III MAINTENANCE MANUAL 18 SPARE PARTS Burner G18 SP...
Страница 20: ...PART III MAINTENANCE MANUAL 20 Burners PG25 SP PG30 TN...
Страница 29: ...APPENDICX COMPONENTS CHARACTERISTICS 29...
Страница 30: ...APPENDICX COMPONENTS CHARACTERISTICS 30...
Страница 31: ...APPENDICX COMPONENTS CHARACTERISTICS 31...
Страница 32: ......