OpenScape Desk Phone CP200/CP205/CP400/CP600 HFA, Administration Manual
81
Administration
System Settings
3.5.11.2
Access control
The CCE access
parameter controls TCP and UDP access for the CCE (CommsChannel
Extender). This affects the operation of the OpenStage Manager, local CTI access, and HPT
access. When Disable is selected, both TCP and UDP are disabled. With Enable, there are no
restrictions.
With
Factory reset claw,
the ’hooded claw’ keypad mechanism to initiate a factory reset with-
out requiring an authenticated access can be enabled or disabled.
The
Serial port
parameter controls access to the serial port. When set to No password, a ter-
minal connected to the port can interact with the phone’s operating system without restric-
tions. When Passwd reqd is selected, the serial port requires a password for access (root user
is not available). When Unavailable is chosen, the serial port is not accessible.
As a prerequisite, the root user needs to create a user and to define a password via Serial
Access, so that access can be granted when the Password required prompt is issued.
Administration via WBM
System > Security > Access control
Administration via Local Phone
|
---
Administration
|
---
System
|
---
Security
|
---
Access control
|---
CCE access
|---
Factory reset claw
|
---
Serial port
Factory reset claw
Access control
Submit
Reset
Serial port Unavailable
CCE access Enable