Base stations
Base station synchronisation
6.2.2 List of synchronised base stations
All activated base stations contained in the
Connected base stations
list ( p. 27) appear in the
Base station
synchronization
list.
Settings
Base stations
Synchronization
For each registered base station the following information is shown:
6.2.3 Actions
Setting up the base station synchronisation
Select the cluster to which the base should be assigned to from the
Cluster
option menu.
Base stations only synchronise within the same cluster, meaning that a handover of a handset from one cluster
to a neighbouring cluster is not possible. The DECT multicell system can manage up to nine clusters.
Select the synchronisation level for the base station from the
DECT Level
option menu.
MAC address
Hardware address of the base station. With this address the device is uniquely identified
within the LAN.
Base station
Name of the base station.
DECT manager
Name of DECT manager the base station belongs to.
Currently always
local
: The base station belongs to the configuring device.
Cluster
Number of the cluster to which the base is assigned.
DECT Level
Synchronisation level within the sync hierarchy.
LAN Master
The base station acting as LAN master is marked by a .
Sync Slave
Indicates if the base station is synchronised via DECT or via LAN. For the Sync master
there is no entry in this column.
Status
Synchronisation status of the base station:
0
Offline
Not available
1
Deactivated
Available but not activated
2
No sync
Activated but not synchronised
3
Sync
Activated and synchronised
4
Sync Overload
Synchronised but DECT overload