Page-24
BevFlex-4X Installation Manual Rev 2.23 November 2019
Feed Unit DC resistance measurements:
The resistance measured with an Ohmmeter from the
center pins of all four of the “F” connectors to their
respective outer shields should measure less than 1 Ohm showing that all the transformer windings are intact.
The resistance measured with an Ohmmeter from the antenna forward “F” connector threads to the antenna
reverse “F” connector threads should measure less than 1 Ohm.
The resistance measured with an Ohmmeter from either the antenna forward “F” connector or the antenna
reverse “F” connector should measure as an open circuit to shield of either the A or B feedline “F” connectors.
Switch Unit DC resistance measurements:
Here are some simple tests with an Ohmmeter to check the functionality of the Switch Unit.
If a transmitter or transceiver accidentally feeds RF power into the Rx port of the control box, a micro-fuse will
open to protect the BevFlex-4X receiving antenna components. You can easily check the condition of this fuse
by measuring the resistance from the center pin of the Rx connector to shield ground. The resistance should
measure approximately 8 Ohms. If this port measures open, the fuse has blown. With the direction switch in the
“Forward” position, the resistance reading from the center pin of the A port to shield should be approximately 75
Ohms. With the direction switch in the
“Forward” position, the resistance reading from the center pin of the B port
to shield should be approximately 1 Ohm. This is the resistance of the transformer winding.
With the direction switch in the “Reverse” position, the resistance reading from the center pin of the B port to
shield
should be approximately 75 Ohms. With the direction switch in the “Reverse” position, the resistance
reading from the center pin of the A port to shield should be approximately 1 Ohm. This is the resistance of the
transformer winding.
10.
Warranty and Support Information
The BevFlex-4X is warranted for parts and workmanship for a period of one year from the time of purchase. Unified
Microsystems will repair or replace failed units at its discretion. Physical or lightning damage is not covered under
warranty.
Unified Microsystems may make changes to the design or specifications without notice.
Support
Support for Unified Microsystems products is available by email. [email protected] Include the product name
(BevFlex-4X) in the subject line for the fastest response.
Disclaimer
Installing antennas can be dangerous. Use caution when installing your BevFlex-4X antenna system. Stay away from
power lines. Unified Microsystems is not responsible for injuries sustained while installing its products.
Always disconnect your BevFlex-4X antenna and all other antennas when not operating to prevent lightning damage.
Unified Microsystems is not responsible for injuries or equipment damage due to improper installation, lightning, or
similar events.
Unified Microsystems
PO Box 133
Slinger, WI 53086