Issue Number: 1

Figure 2-1 Rating label and product identification

3

Mechanical installation

The drives can be panel mounted with 0 mm space between the drives. For further information on 
mechanical installation refer to the 

Unidrive M200 / M201 User Guide.

To remove the terminal cover, use a flat bladed screwdriver to rotate the terminal cover locating clip 
by approximately 30° in a counter clockwise direction, and then slide the cover down.

Table 3-1 Recommended torque settings

Drive

Size

H

W

D

M1

M2

A

B

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

mm

in

1

160

6.30

75

2.95

130

5.12

143

5.70

53

2.08

5

0.2

0.00

0.00

100

3.93

2

205

8.07

78

3.07

150

5.91

194

7.63

55

2.17

5

0.2

3

226

8.90

90

3.54

160

6.30

215

8.46

70.7

2.80

5

0.2

4

277 10.91 115

4.53

175

6.89

265 10.43

86

3.40

6

0.23

Model size

Terminal block description

Torque settings

All

Control terminals

0.2 N m (0.15 Ib ft)

Relay terminals

0.5 N m (0.37 Ib ft)

1

Power terminals

0.5 N m (0.37 Ib ft)

2, 3, 4

1.4 N m (1.03 Ib ft)

Derivative

Electrical Specifications

M200 -

03

4

00073

Product line:

Frame size:

Voltage rating

:

Current Rating :

Heavy Duty current rating x10

Drive Format :

A – AC in AC out

A

1 - 100 V (100 - 120 10 %)

- 400 V (380 - 480 10 %)

5 - 575 V (500 - 575 10 %)

6 - 690 V (500 - 690 10 %)

2 - 200 V (200 - 240 10 %)

4

±

±

±

±

±

A

W

M2

M2

B

D

B

A

H M1

11 mm

(0.43 in)

Cover

release