8.4.2
jumper und DIP-switch settings
jumper ME1-ME3
ME1+2 sampling latch channel 1+2: jumper left 2.2µF/right 10 µF
ME3 reference voltage: jumper left Uref = 7.06V/right Uref = 6.79V
DIP-switch SW1
switch 1-4 filter setting channel 1
either turn on only 1 or 2, or turn on none*
F limit = 1KHz (33nF) (default 1+2= OFF)
1 F limit = 100Hz (220nF II 33nF) (1=ON, 2=OFF)
2 F limit = 355Hz (47nF II 33nF) (2=ON, 1=OFF)
either turn on only 3 or 4, or turn on none*
3 with filter (default 3=ON, 4=OFF)
4 without filter (4=ON, 3=OFF)
switch 5-8 filter setting channel 2
either only 5 or 6, or turn on none*
5 with filter (default 5=ON, 6=OFF)
6 without filter (6=ON, 5=OFF)
either only 7 or 8, or turn none on*
F limit = 1KHz (33nF) (default 7+8= OFF)
7 F limit = 100Hz (220nF II 33nF) (7=ON, 8=OFF)
8 F limit = 355Hz (47nF II 33nF) (8=ON, 7=OFF)
*never both at the same time, otherwise this can lead to malfunctions or damage to the electronics!
ME1
ME2
ME3
on
off