background image

8

UHF CB Radio

UNIDEN UH515SX-2NB

Group Scan(GS) Mode

To change between OS and GS scan;

1. Press 

(menu)

 three times. 

GS

 setting flashes.

2. Press 

(ch)

   or   or 

(vol) 

 or 

 to change the selection.

3.  Press & hold 

(menu)

 to save and exit. 

To initiate scanning,

1.  When 

vol

 

 scan

 is pressed during Group Scan Mode, Group Scanning     

 

begins.

2.   To deactivate GS scanning, press 

(PTT) 

or press and hold 

vol

 

 (scan)

.

NOTE

1.  If SCAN is deactivated while it is tuned to an active

     channel, the UH515SX-2NB will stay on that active channel.

 

     If none of the channels re-active, the radio will reinstate the 

 

     Scan start channel.

2.  If OS/GS Scanning is initiated when there are no channels 

     programmed in OS/GS memory, an error tone will be heard 

     and scanning will not start.

Priority Channel Watch During Group Scan

The feature monitors the Priority channel every 1.5 secs during GS.

1. Press 

(menu)

 four times.

 Pr

 setting flashes.

2. Press 

(ch)

   or   or 

(vol) 

 or   to select the desired channel.

3.  Press & hold 

(menu)

 to save and exit. 

Programming Scan Channels

1.  Select which Scanning Mode you wish to use on the channel OS or GS Mode.

2.  Select the channel you want to store by pressing 

(ch)

   or  .

3.  Press and hold  

vol  (mem) 

to store.

 

M

 icon appears.

4.  To remove the channel from Memory, Press and hold 

vol  (mem)

 to 

 

remove. 

M

 icon disappears.

Drop-Out Delay

While scanning, the radio stops at a busy channel and receives a signal. When

the received signal is over, the unit will wait for 2 seconds for the return of the

signal, otherwise, the radio resumes scanning.

Operation

Содержание UH515SX-2NB

Страница 1: ...UH515SX 2NB UHF CB Radio For more exciting new products please visit our website Australia www uniden com au New Zealand www uniden co nz...

Страница 2: ...lt Clip 2 Charging Cradle with AC Adaptor Heavy Duty Earpiece MIC EM 082 2 NiMH Battery Pack 2 Carabiner Clip 2 14 Channel Indicator 15 TX Transmit 16 RX Signal Receive 17 HI Power Hi Lo 18 M Memory C...

Страница 3: ...NB for long periods Uniden recommends removing the batteries OLD NEW To avoid damage to the unit do not mix old and new batteries To install the batteries 1 Make sure your radio is off 2 Release the b...

Страница 4: ...harging 3 Before operating the UH515SX 2NB charge the battery pack for 16 hours NOTE Do not charge alkaline or non rechargeable batteries User License Information The citizen band radio service is lic...

Страница 5: ...attery level becomes low the battery indicator icon on the display begins flashing When the batteries in the unit are low the unit will go into a battery low mode The Transmit mode is disabled Replace...

Страница 6: ...be adjusted from 0 min volume to 7 maximum volume Press vol or to increase or decrease the volume level U and the current volume level will flash on the display Keypad Lock To prevent accidental entri...

Страница 7: ...it The unit cannot transmit continually for more than 3 minutes If the user transmits continually for more than 3 minutes the unit stops transmitting a signal The TX icon and the Channel segment will...

Страница 8: ...can searches all the channels and frequencies in its memory continuously GS Scan is similar to OS scan but has the added ability to monitor the priority channel every 1 5 seconds Scanning searchs for...

Страница 9: ...mmed in OS GS memory an error tone will be heard and scanning will not start Priority Channel Watch During Group Scan The feature monitors the Priority channel every 1 5 secs during GS 1 Press menu fo...

Страница 10: ...e screen 2 Press ch or or vol or to change the selection r appears for CH01 CH08 and n appears for CH41 CH48 when duplex is selected 3 Press hold menu to save and exit NOTE Contact your retailer for a...

Страница 11: ...pressing the PTT key While headset microphone is not connected VOX function is inactive even if VOX level setting is from 1 to 5 VX appears when VOX level setting is from 1 to 5 1 Press menu seven tim...

Страница 12: ...ne minute then an error tone will sound Key Beep Assures the user that the keypad has been properly pressed by emitting a beep tone This tone can be switched on or off 1 Press menu nine times bP setti...

Страница 13: ...nnel use to narrowband channel use This allows for additional channels to be added up to 80 Channels This simply means that the new narrowband radio you have purchased will have more channels than old...

Страница 14: ...rst purchased either in Australia or New Zealand and will expire one 1 year from the date of the original retail sale If a warranty claim is made this warranty will not apply if the Product is found b...

Страница 15: ...under either the COMPETITION AND CONSUMER ACT 2010 Australia or the CONSUMER GUARANTEES ACT New Zealand as the case may be none of which can be excluded Procedure for obtaining warranty service Depend...

Страница 16: ...THANK YOU FOR BUYING A UNIDEN PRODUCT 2012 Uniden Australia Pty Limited Uniden New Zealand Ltd Printed in PRC U01UT953ZZZ 0...

Отзывы: